2014
DOI: 10.1016/j.colsurfa.2013.09.028
|View full text |Cite
|
Sign up to set email alerts
|

Direct measurement of the interaction of model food emulsion droplets adhering by arrested coalescence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 18 publications
0
5
0
Order By: Relevance
“…Due to the higher stiffness of the capillaries, these have a force resolution of ~1 nN which is two orders of magnitude higher than MFS. Using CCFA, the interaction forces between vesicles [56] and food emulsion droplets [57] were investigated. Although MFS and CCFA are very similar, they differ in how the cantilevers are manufactured.…”
Section: Development Of the Approachmentioning
confidence: 99%
“…Due to the higher stiffness of the capillaries, these have a force resolution of ~1 nN which is two orders of magnitude higher than MFS. Using CCFA, the interaction forces between vesicles [56] and food emulsion droplets [57] were investigated. Although MFS and CCFA are very similar, they differ in how the cantilevers are manufactured.…”
Section: Development Of the Approachmentioning
confidence: 99%
“…Partial coalescence can also be observed in o/w emulsions containing solid particles that are completely wetted by the oil. Frostad et al [ 105 ] measured the interaction forces between two solid-in-oil-droplets attached to two capillaries immersed in water. The magnitude of the forces measured between drops as they came into close contact were consistent with those predicted assuming that capillary bridges form between the drops [ 105 ].…”
Section: Coalescing Dropsmentioning
confidence: 99%
“…Frostad et al [ 105 ] measured the interaction forces between two solid-in-oil-droplets attached to two capillaries immersed in water. The magnitude of the forces measured between drops as they came into close contact were consistent with those predicted assuming that capillary bridges form between the drops [ 105 ]. Pawar et al [ 106 ] observed coalescence between partially crystalline oil droplets, as the elastic modulus of the oil was varied by altering the concentration of fat crystals in the drops.…”
Section: Coalescing Dropsmentioning
confidence: 99%
“…Stress relaxation data for sample #2 are fitted to a stretched exponential model following Frostad et al [ 30 ] to determine the stretching exponent, β , and characteristic relaxation time, t c , for the neurosphere. Note that, sequentially, the maximum in the force and in position decreases with subsequent compressions.…”
Section: Resultsmentioning
confidence: 99%
“…We characterized the mechanical properties of the neurospheres using the CCFA. [ 28,30–32 ] The device uses a cantilevered capillary (inner diameter or ID 50 μm, outer diameter or OD 360 μm) to aspirate and hold a single neurosphere within a reservoir of PBS. A second, rigid capillary (ID 5 μm, OD 360 μm) then compresses the neurosphere against the cantilevered capillary ( Figure ).…”
Section: Methodsmentioning
confidence: 99%