1992
DOI: 10.1088/0026-1394/29/1/006
|View full text |Cite
|
Sign up to set email alerts
|

Direct Measurements of the Dielectric Virial Coefficients of4He between 3 K and 18 K

Abstract: The second and third dielectric virial coefficients of 4He have been measured by the symmetrical gasexpansion technique of Buckingham, Cole and Sutter for six isotherms between 3,OO K and 17,68 K. The effects of helium adsorption are important, and are considered in detail. No temperature dependence of the second coefficient is seen at a level of 6b= &0,008 cm3mol-', and average values of the second and third coefficients are b = 0,006 (10) cm3 mol-and c = -5 (4) cm6 mol-', respectively. The uncertainty for b … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
17
1

Year Published

1997
1997
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(20 citation statements)
references
References 21 publications
1
17
1
Order By: Relevance
“…[32] and [33] in the temperature range of the present study is used as an estimate of the uncertainty in the value of B ε . For C ε , insufficient literature data exist to determine temperature dependence, so a temperature-independent value is assumed, derived from the average of the only theoretical calculation (at room temperature) [34] and several experimental results (at various temperatures) [35][36][37][38]; the large uncertainty of C ε comes from the standard deviation of these values, yet contributes little to the uncertainty in (T − T 90 ) at the densities used in the present study (see Table 3). The value and uncertainty of A µ come from an interpretation of the calculation of Ref.…”
Section: Procedures For Determining T From a Single Microwave Scanmentioning
confidence: 99%
“…[32] and [33] in the temperature range of the present study is used as an estimate of the uncertainty in the value of B ε . For C ε , insufficient literature data exist to determine temperature dependence, so a temperature-independent value is assumed, derived from the average of the only theoretical calculation (at room temperature) [34] and several experimental results (at various temperatures) [35][36][37][38]; the large uncertainty of C ε comes from the standard deviation of these values, yet contributes little to the uncertainty in (T − T 90 ) at the densities used in the present study (see Table 3). The value and uncertainty of A µ come from an interpretation of the calculation of Ref.…”
Section: Procedures For Determining T From a Single Microwave Scanmentioning
confidence: 99%
“…The second and third dielectric virial coefficients of helium, b and c , are approximately a factor of 100 smaller than the second and third density virial coefficients ( B and C ); however, the absolute uncertainties in the two sets of quantities are comparable. The theoretical and experimental results for the second dielectric virial coefficient b for helium were reviewed by White and Gugan [ 8 ] in 1992. They measured b in the range from 3 K to 18 K obtaining the result b = (−0.001 ± 0.004) cm 3 mol −1 .…”
Section: Quantities From Theory and Rmentioning
confidence: 99%
“…This analysis may be considered optimistic because the deformation of conventional capacitors under pressure [ 8 ] is more complex than that assumed here. Capacitors are assembled objects, not simply samples of a uniform material.…”
Section: Quantities To Be Measuredmentioning
confidence: 99%
See 1 more Smart Citation
“…The present results can be applied to many problems in metrology; here we mention a few. Low-density helium is used in primary, constant-volume, gas thermometry [ 1 ]; primary, dielectric-constant gas thermometry [ 2 ]; and in interpolating gas thermometry (required by ITS-90 in the temperature range 3 K to 24.6 K) [ 3 ]. These applications require the extrapolation of measurements to zero pressure.…”
Section: Introductionmentioning
confidence: 99%