2019
DOI: 10.1103/physreva.100.022707
|View full text |Cite
|
Sign up to set email alerts
|

Direct observation of interatomic Coulombic decay and subsequent ion-atom scattering in helium nanodroplets

Abstract: We report on the experimental observation of Interatomic Coulombic Decay (ICD) in pure 4 He nanoclusters of mean sizes between N~5000-30000 and the subsequent scattering of energetic He + fragments inside the neutral cluster by using Cold Target Recoil Ion Momentum Spectroscopy (COLTRIMS). ICD is induced in He clusters by using VUV light of hν = 67 eV from the BESSY II synchrotron. The electronic decay creates two neighboring ions in the cluster at a well-defined distance. The measured fragment energies and an… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
18
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(19 citation statements)
references
References 50 publications
1
18
0
Order By: Relevance
“…In larger clusters collisions, fragmentation into complexes that include neutrals, and postdecay nuclear dynamics all lead to a blurring of the sought-for ion signal. 258 , 259 Pure spectroscopy of energetic ions is capable to detect ICD only in some favorable cases and has mostly been superseded by powerful coincidence methods, which will be described in the next section.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…In larger clusters collisions, fragmentation into complexes that include neutrals, and postdecay nuclear dynamics all lead to a blurring of the sought-for ion signal. 258 , 259 Pure spectroscopy of energetic ions is capable to detect ICD only in some favorable cases and has mostly been superseded by powerful coincidence methods, which will be described in the next section.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Early experiments on ICD using the COLTRIMS technique can be found, for example, in refs ( 2 , 8 , 15 , 16 , 29 , 57 , 58 , 60 , 187 189 , 198 , 215 , and 296 303 ); later work in refs ( 23 , 28 , 196 , 203 , 205 , 245 , 247 , 248 , and 304 315 ); and most recent work in refs ( 54 , 107 , 192 , 201 , 249 , 250 , 259 , and 316 324 )…”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Superfluid helium (He) nanodroplets are ideal model systems to study electronic relaxation and ionization dynamics, not only because of the extremely weak interatomic binding of the He atoms to each other and to dopants, but also because the simple electronic structure of the He atom greatly facilitates the interpretation of electron spectra. [11][12][13] ICD and ICD-like decay mechanisms have been studied in both pure He droplets [13][14][15][16][17] and in droplets doped with various metal atoms and molecules. [18][19][20][21][22][23][24][25][26] In the case where atomic or molecular impurities are ionized through resonant valence-shell excitation of the He droplet, the ICD process resembles what traditionally has been termed Penning ionization by analogy to collisional ionization in a crossed beam experiments involving metastable rare gas atoms.…”
Section: Decay (Icd) Takes Places Either Between Two Excited He Atoms...mentioning
confidence: 99%
“…Furthermore, charged particle impact, such as pulsed electron guns [6] or alpha-particle impact [7] have also been used. ICD signatures are probed by traditional methods of electron [8] and ion [9] spectroscopy, including various coincidence techniques [10]. Access to time-resolved ICD dynamics has also been possible by the contemporary pump-probe approaches [5,11], specifically, by light field streaking techniques [12].…”
Section: Introductionmentioning
confidence: 99%