2018
DOI: 10.1080/00032719.2018.1485025
|View full text |Cite
|
Sign up to set email alerts
|

Direct Quantification of Major and Trace Elements in Geological Samples by Time-of-Flight Mass Spectrometry with a Pulsed Glow Discharge

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 53 publications
0
5
0
Order By: Relevance
“…Several sample preparation procedures were applied in the current study: direct measurements with no sample preparation, powdering and pressing in Al foil as described previously, 42,51 and covering with silver conductive paint; more details can be found elsewhere 24,45 …”
Section: Methodsmentioning
confidence: 99%
“…Several sample preparation procedures were applied in the current study: direct measurements with no sample preparation, powdering and pressing in Al foil as described previously, 42,51 and covering with silver conductive paint; more details can be found elsewhere 24,45 …”
Section: Methodsmentioning
confidence: 99%
“…After pressing the powder into an aluminum tablet, pulsed GD-TOF-MS allowed the detection of As, B, Ce, Co, Dy, Fe, K, La, Lu, Mg, Mn, Na, Nb, Nd, P, Pr, Rb, S, Sb, Si, Sm, Th, Ti, and U in ore sample. 45 Nevertheless, the biggest problem GD-MS still suffers from is the accurate quantification for elements, in spite of the utilization of relative sensitivity factors and matrix-matched standards. 46 Even so, GD-MS displays versatility, e.g., pulsed GD-TOF-MS was reported to analyze elemental oxidation states from the solid material, 47,48 and GD-MS/MS to analyze pesticide in food sample.…”
Section: Sensitivity and Multielemental Analysis In Agrometallomicsmentioning
confidence: 99%
“…For another, TOF-MS is popularly coupled with pulsed GD to fulfill the simultaneous multielemental analysis in depth profiling applications. After pressing the powder into an aluminum tablet, pulsed GD-TOF-MS allowed the detection of As, B, Ce, Co, Dy, Fe, K, La, Lu, Mg, Mn, Na, Nb, Nd, P, Pr, Rb, S, Sb, Si, Sm, Th, Ti, and U in ore sample . Nevertheless, the biggest problem GD-MS still suffers from is the accurate quantification for elements, in spite of the utilization of relative sensitivity factors and matrix-matched standards .…”
Section: Sensitivity and Multielemental Analysis In Agrometallomicsmentioning
confidence: 99%
“…The most widely adopted method in previous studies is to compact the soil with high purity metal (such as aluminium, silver, copper and tantalum and so on) as a conductive binder to form a pin or plate-shaped cathode. [16][17][18]21 However, the soils are hard to be mixed with conductive binder uniformly to form pin or plate-shaped cathodes with a certain mechanical strength, the process of which is often time-consuming and easy to bring in secondary contamination. The second approach is to cover a metallic secondary cathode diaphragm at the surface of the soil plate, allowing the surface covered by a thin metallic layer during sputtering.…”
Section: -27mentioning
confidence: 99%
“…6,7 Hence, the accurate and reliable determination of trace elements in soil is vital of importance in the point of environmental pollution. Atomic spectrometry (AES/AAS), 8 inductively coupled plasma mass spectrometry (ICP-MS), [9][10][11] instrumental neutron activation analysis (INNA), 12,13 X-Ray fluorescence spectrometry (XRF), 14 laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) 15 and glow discharge mass spectrometry (GD-MS) [16][17][18][19][20][21][22] has been used in geology and geochemistry surveys. However, due to the refractory nature of the soil samples, the sample preparation is time-consuming with the risk of sample contamination from chemical reagents in dissolve process when utilizing the conventional solutionbased approaches, such as ICP.…”
Section: Introductionmentioning
confidence: 99%