2014
DOI: 10.1088/0957-0233/25/9/095009
|View full text |Cite
|
Sign up to set email alerts
|

Direct thrust measurement stand with improved operation and force calibration technique for performance testing of pulsed micro-thrusters

Abstract: A robust stand for directly measuring pulsed thrust from micro-thrusters is presented. The method of electrostatic discs for in situ calibration was improved upon and simplified to allow convenient and accurate thrust measurement. The novel use of frictionless liquid gallium metal power interfaces for µN-level force measurement stands was also demonstrated. A series of detailed verification tests were performed to characterize the thrust stand’s overall operating range and accuracy. The stand can test single a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 14 publications
0
10
0
Order By: Relevance
“…The stand detects displacement due to impulsive thrust by means of a high-resolution fiber-optic laser displacement sensor. The stand allows for the mounting of multiple thrusters for a single thrust test sequence and can measure a wide range of impulse bits (0.3-600 μNs) to a maximum precision of 2% [15].…”
Section: Thrust Measurement Systemmentioning
confidence: 99%
“…The stand detects displacement due to impulsive thrust by means of a high-resolution fiber-optic laser displacement sensor. The stand allows for the mounting of multiple thrusters for a single thrust test sequence and can measure a wide range of impulse bits (0.3-600 μNs) to a maximum precision of 2% [15].…”
Section: Thrust Measurement Systemmentioning
confidence: 99%
“…Low-power vacuum arc thrusters have the known problem of a limited lifetime, which may vary from 10 3 ( 26 ) to 10 5 pulses ( 27 ), while the special constructions with the cathode feeding mechanism allow the achievement of several million pulses ( 28 ). In our previous study ( 29 ), we found that the lifetime of the μCAT firing in the high-power regime can be extended to more than 1 million pulses by optimizing the anode-cathode gap (extending it to around 1 mm) and providing the magnetic field, causing the movement of cathodic spot along the cathode surface.…”
Section: Discussionmentioning
confidence: 99%
“…Notice that at the current state the differential force measuring system is considered as portable and stand-alone force measurement system. With reference to jet propulsion technologies, our differential force measurement system may be considered as potential applications in the field of research and development for the calibration and characterization of pulsed micro-thrusters [31][32][33].…”
Section: Discussionmentioning
confidence: 99%