Abstract: The effect of a dc on the interdiffusivity D in the Cu-Ni system was investigated over the temperature range of 650-850°C and at current densities in the range of 0 -1000 A cm −2 . Interdiffusivities were calculated using the Sauer-Freise-den Broeder method and the values calculated in the absence of a current were in agreement with previously published results. The influence of the current on D depended on its direction relative to the two interfaces in the trilayered Cu-Ni-Cu samples. When the electronic flo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
14
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
6
3
1

Relationship

1
9

Authors

Journals

citations
Cited by 43 publications
(16 citation statements)
references
References 21 publications
2
14
0
Order By: Relevance
“…Electromigration can also lead to interdiffusion at interfaces or phase separation in alloys. When the current was flowing from Ni to Cu, a marked increase of the interdiffusion was observed as compared to the case where the current was flowing from Cu to Ni (Zhao et al, 2007).…”
Section: A Electromigration Of Alloysmentioning
confidence: 86%
“…Electromigration can also lead to interdiffusion at interfaces or phase separation in alloys. When the current was flowing from Ni to Cu, a marked increase of the interdiffusion was observed as compared to the case where the current was flowing from Cu to Ni (Zhao et al, 2007).…”
Section: A Electromigration Of Alloysmentioning
confidence: 86%
“…8), 9) In the case of the formation of solid solution, the effect of the current on the interdiffusivity in the Cu-Ni system was investigated over a temperature range of 923-1123 K and at current values in the range of 0-1000 A. 10) When the electronic flow was from Ni to Cu, interdiffusivity showed a marked increase relative to copper content, but it was unchanged when the electronic flow was from Cu to Ni. The sign of effective valance for Ni and Cu self-diffusion are both negative.…”
Section: Introductionmentioning
confidence: 99%
“…Zhao et al [17] investigated interdiffusion coefficient of Cu and Ni in the temperature range of 650 and 850°C as presented in Fig. 2(c).…”
Section: Interdiffusionmentioning