2012
DOI: 10.1016/j.lwt.2012.02.016
|View full text |Cite
|
Sign up to set email alerts
|

Discrimination between defective and non-defective roasted coffees by diffuse reflectance infrared Fourier transform spectroscopy

Abstract: a b s t r a c tThe objective of this work was to evaluate the feasibility of employing Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) for discrimination between defective and non-defective coffees after roasting and grinding. Defective (black, immature and sour) and non-defective Arabica coffee beans were submitted to light, medium and dark roasts at 220, 235 and 250 C. Principal Components Analysis of the DRIFTS spectra (normalized or not) and of the first derivatives of the spectra prov… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

7
44
0
2

Year Published

2013
2013
2023
2023

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 76 publications
(53 citation statements)
references
References 27 publications
7
44
0
2
Order By: Relevance
“…These two peaks, in conjunction with the stretching absorption of carbonyl (C=O) bond at approximately 1740 cm -1 , are associated with the ester group of triglyceride in lipid (fat) (Craig et al 2012), which is present in both samples. A similar observation of the lipid FTIR peaks has been reported for corn-based distillers' grains containing corn oil (Zarrinbakhsh et al 2013).…”
Section: Ftir Spectroscopymentioning
confidence: 93%
“…These two peaks, in conjunction with the stretching absorption of carbonyl (C=O) bond at approximately 1740 cm -1 , are associated with the ester group of triglyceride in lipid (fat) (Craig et al 2012), which is present in both samples. A similar observation of the lipid FTIR peaks has been reported for corn-based distillers' grains containing corn oil (Zarrinbakhsh et al 2013).…”
Section: Ftir Spectroscopymentioning
confidence: 93%
“…Furthermore, DRIFTS was shown to be appropriate for the analysis of roasted coffees, providing satisfactory discrimination between Arabica and Robusta varieties (Kemsley et al, 1995;Suchánek et al, 1996), between regular and decaffeinated coffees (Ribeiro et al, 2010) and between non-defective and defective coffees (Craig, Franca, & Oliveira, 2012b). However, no attempts were reported in the literature on the use of this methodology for the analysis of adulteration of ground and roasted coffee samples.…”
Section: Introductionmentioning
confidence: 99%
“…Several literatures have characterized the properties of defective coffee beans to improve the quality of commercial coffee. Published data on the characteristics of defective coffee were described using Fourier transform infrared spectroscopy (Craig et al, 2012), physical, organoleptic and chemical analysis (Franca et al, 2005a), and cup quality (Franca et al, 2005b) to distinguish them from non-defective coffee beans. However, these methods are not common to coffee farmers and screening for coffee defects is only done visually, relying primarily on morphological or sensory properties as basis for the classification of coffee beans.…”
Section: Introductionmentioning
confidence: 99%