2018
DOI: 10.1364/josab.35.001301
|View full text |Cite
|
Sign up to set email alerts
|

Dispersion measurement of ultra-high numerical aperture fibers covering thulium, holmium, and erbium emission wavelengths

Abstract: We present broadband group velocity dispersion (GVD) measurements of commercially available ultra-high numerical aperture fibers (UHNA1, UHNA3, UHNA4, UHNA7 and PM2000D from Coherent-Nufern). Although these fibers are attractive for dispersion management in ultrafast fiber laser systems in the 2 μm wavelength region, experimental dispersion data in literature is scarce and inconsistent. Here we demonstrate the measurements using the spectral interferometry technique covering the typically used erbium, thulium … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
28
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 82 publications
(31 citation statements)
references
References 28 publications
3
28
0
Order By: Relevance
“…The same setup was used for dispersion measurements reported eg. in [38]. All supercontinuum spectra were obtained under pumping from a compact erbium fiber-based femtosecond laser from Menlo Systems (model C-fiber HP), which delivers around 90 fs long, nearly transform-limited, Gaussianshaped pulses, centered at 1560 nm with a repetition rate of 100 MHz.…”
Section: Discussion Of Experimental Results With Physical Fibersmentioning
confidence: 99%
“…The same setup was used for dispersion measurements reported eg. in [38]. All supercontinuum spectra were obtained under pumping from a compact erbium fiber-based femtosecond laser from Menlo Systems (model C-fiber HP), which delivers around 90 fs long, nearly transform-limited, Gaussianshaped pulses, centered at 1560 nm with a repetition rate of 100 MHz.…”
Section: Discussion Of Experimental Results With Physical Fibersmentioning
confidence: 99%
“…The SA was located between the coupler and isolator. The total cavity length was measured as~9.5 m and its cavity group velocity dispersion (GVD) was calculated as -0.64 ps 2 according to the previously measured dispersion values [29,30] The nonlinear transmission of the prepared SA was also measured using lab-made, ~1.5 ps fiber laser with a repetition rate of 24 MHz at 1.93 μm. Figure 4 shows the measured nonlinear transmission with a fitted curve [27]:…”
Section: Resultsmentioning
confidence: 99%
“…The SA was located between the coupler and isolator. The total cavity length was measured as ~9.5 m and its cavity group velocity dispersion (GVD) was calculated as -0.64 ps 2 according to the previously measured dispersion values [29,30]. The laser output was measured by an optical spectrum analyzer (AQ6375, Yokogawa, Tokyo, Japan) a 500-MHz oscilloscope (6050A, Lecroy, Chestnut Ridge, NY, USA), with a 10-GHz photodetector (ET-5010F, EOT, Traverse City, MI, USA), an electrical spectrum analyzer (USB-SA124B, Signalhound, Battle Ground, WA, USA), and an autocorrelator (FR-103MN, Femtochrome Research, Berkeley, CA, We increased the pump power and the laser operated in continuous wave (CW) mode at a pump power of~58 mW.…”
Section: Resultsmentioning
confidence: 99%
“…We then use 3 m of Nufern PM2000D to stretch the soliton and ensure net normal dispersion inside the CPA. We estimated the dispersion of PM2000D using [27] to be 92 ps 2 /km. The stretched pulse then passes a fast-axis blocked PM-isolator (ISO2) with 0.8 dB insertion loss.…”
mentioning
confidence: 99%