2023
DOI: 10.1016/j.talanta.2022.124229
|View full text |Cite
|
Sign up to set email alerts
|

Disposable label-free electrochemical immunosensor based on prussian blue nanocubes for four breast cancer tumor markers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(5 citation statements)
references
References 41 publications
0
5
0
Order By: Relevance
“…The detection limit (DL) calculated based on a signal-to-noise ratio (S/N) of 3 was 0.13 mU/mL. Table 1 summarized the comparison of the analytical performance obtained on different modified electrodes for the detection of CA15-3 using electroluminescence (ECL), photoelectrochemical (PEC) or electrochemical (EC) methods ( Cui et al, 2014 ; Bao et al, 2021 ; Zhong et al, 2021 ; Kongkaew et al, 2023 ; Lin et al, 2023 ). As seen, the electrochemical aptasensor established in this paper has a wide linear range and a low LOD.…”
Section: Resultsmentioning
confidence: 99%
“…The detection limit (DL) calculated based on a signal-to-noise ratio (S/N) of 3 was 0.13 mU/mL. Table 1 summarized the comparison of the analytical performance obtained on different modified electrodes for the detection of CA15-3 using electroluminescence (ECL), photoelectrochemical (PEC) or electrochemical (EC) methods ( Cui et al, 2014 ; Bao et al, 2021 ; Zhong et al, 2021 ; Kongkaew et al, 2023 ; Lin et al, 2023 ). As seen, the electrochemical aptasensor established in this paper has a wide linear range and a low LOD.…”
Section: Resultsmentioning
confidence: 99%
“…The accuracy of the results was confirmed by measuring the electrochemical properties of the reacted and unreacted PBNPs to achieve two complementary measurement modes of signal switching with LODs of 5.2 μU mL −1 and 0.41 μU mL −1 , respectively. Kongkaew et al [82] proposed a multi-electrode array consisting of four working electrodes, shared reference electrodes, and auxiliary electrodes for the detection of four breast cancer tumor markers (CEA, CA125, CA153, and CA199). In addition, Zhu et al [83] developed an isolated photoimmunoassay for CEA using polydopamine-encapsulated PBNPs as a signal marker.…”
Section: Electrochemical Immunoassaysmentioning
confidence: 99%
“…Kongkaew S. et al [ 48 ] report that the multi-electrode array (MEA) was fabricated in the presence of working, reference, and auxiliary electrodes. Prussian blue nanocubes (PBNCs) were synthesized and applied by cyclic voltammetry.…”
Section: Application Of Sensorsmentioning
confidence: 99%