Dissipation of oxaziclomefone residues from rice, soil, and paddy field water using carbon nanotube-based QuEChERS and HPLC-MS analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 32 publications
0
3
0
Order By: Relevance
“…The detection limit (LOD) and quantification limit (LOQ) were 0.0023-0.0033 mg/kg and 0.0082-0.0115 mg/kg, respectively (Table 1). This indicated that the analysis method meets the requirements of the "Guidelines for Pesticide Residues Experiment (NY/788-2018)" [28]. The hydrolysis kinetics curves and hydrolysis rate curves for pydiflumetofen at different initial concentrations are shown in Figure 2, while the hydrolysis kinetics model parameters are shown in Table 2.…”
Section: Precision Results Lod and Loqmentioning
confidence: 79%
See 1 more Smart Citation
“…The detection limit (LOD) and quantification limit (LOQ) were 0.0023-0.0033 mg/kg and 0.0082-0.0115 mg/kg, respectively (Table 1). This indicated that the analysis method meets the requirements of the "Guidelines for Pesticide Residues Experiment (NY/788-2018)" [28]. The hydrolysis kinetics curves and hydrolysis rate curves for pydiflumetofen at different initial concentrations are shown in Figure 2, while the hydrolysis kinetics model parameters are shown in Table 2.…”
Section: Precision Results Lod and Loqmentioning
confidence: 79%
“…At different levels of addition, the average recovery rate of pydiflumetofen in the soil was 90.16% to 101.11%, with a relative standard deviation of 1.62-6.75%. When the recovery is between 70~120% and RSD < 15%, it indicates that the analytical residue method has a good accuracy and precision [28]. LOD is defined as the concentration of pydiflumetofen when the signal-to-noise ratio exceeds 3 (S/N = 3) in the matrix extraction, while LOQ is defined as the concentration of pydiflumetofen when the signal-to-noise ratio exceeds 3 (S/N = 10) in the matrix extraction [27,29].…”
Section: Precision Results Lod and Loqmentioning
confidence: 99%
“…In addition, GC-MS is relatively expensive, as it relies on sophisticated instruments and highly trained professionals. Liquid chromatography-(LC-) MS can separate thermally unstable and nonvolatile samples and thus can complement the limitations of GC [21]. LC-MS is also associated with highly accurate, sensitive, and reliable results.…”
Section: Traditional Methodsmentioning
confidence: 99%