2020
DOI: 10.1097/md.0000000000018330
|View full text |Cite
|
Sign up to set email alerts
|

Distal radial artery access in the anatomical snuffbox for coronary angiography and intervention

Abstract: Background: To explore the feasibility and safety of coronary angiography (CAG) and percutaneous coronary intervention (PCI) via the distal radial artery in the anatomical snuffbox. Methods: Ninety two patients who underwent CAG or PCI through distal radial artery access at The Second Affiliated Hospital of Zhejiang Chinese Medical University from September 2017 to March 2018 were included in our study. We collected baseline characteristics, number, and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
16
0
2

Year Published

2020
2020
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(25 citation statements)
references
References 20 publications
5
16
0
2
Order By: Relevance
“…A position for the patient was described in previous studies ( 11 , 12 ). The left upper arm was placed comfortably on the left side of the patient after the puncture.…”
Section: Methodsmentioning
confidence: 99%
“…A position for the patient was described in previous studies ( 11 , 12 ). The left upper arm was placed comfortably on the left side of the patient after the puncture.…”
Section: Methodsmentioning
confidence: 99%
“…The left hand is placed such a way which is more comfortable for the operator and the patient. 17 After maintaining proper sterility, once the wrist is prepared, access to the artery can be obtained at ease. 10,11 Use of ultrasound may be of beneficial to use for locating the artery, and also may give an idea to the diameter of the vessel and thus help the operator to choose actual size of catheter and sheaths while doing the procedure.…”
Section: Figurementioning
confidence: 99%
“…One need to feed the guide wire gently. 17 Before introduction of the sheath along the guide wire, a small skin incission may be needed to avoid the sheath damage in some cases. After the insertion of the sheath over the short guide wire, the dilator along with the wire may be removed.…”
Section: Figurementioning
confidence: 99%
See 1 more Smart Citation
“…Em um estudo envolvendo 92 pacientes submetidos a procedimentos coronarianos por meio do acesso transradial distal onde quatro casos foram à esquerda e 88 à direita, Yu et al 84 obtiveram sucesso técnico em todos os quatro casos de acesso da ARD esquerda, e 84 (95,4%) dos acessos da ARD direita, sendo realizada conversão para acesso transradial convencional nos casos de insucesso. Destes quatro casos de insucesso, um deveu-se a vasoespasmo e três pelo insucesso da punção arterial apesar de mais de cinco tentativas.…”
Section: Sucesso Técnicounclassified