2003
DOI: 10.1046/j.1540-8167.2003.03205.x
|View full text |Cite
|
Sign up to set email alerts
|

Distal Right Ventricular Coil Position Reduces Defibrillation Thresholds

Abstract: DFTs are significantly reduced with the distal RV configuration compared to the proximal RV configuration. Defibrillation leads should be designed with the shortest tip to coil distance that can be achieved without compromising ventricular fibrillation sensing.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2005
2005
2012
2012

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 26 publications
0
7
0
1
Order By: Relevance
“…Repositioning of the RV lead is a consideration if the initial lead location is not ideal. A distal shock coil far from apex may elevate DFTs [41,42], and implanting the RV lead near septum and apex may lower DFTs [43][44][45]. Adding a shock coil in the middle cardiac vein [46][47][48][49][50] or azygous vein or implanting a subcutaneous array electrode [51][52][53][54] may be a more successful strategy for low DSM patients who failed to convert ventricular fibrillation with maximum delivered energy, especially in right-sided implant patients.…”
Section: Discussionmentioning
confidence: 99%
“…Repositioning of the RV lead is a consideration if the initial lead location is not ideal. A distal shock coil far from apex may elevate DFTs [41,42], and implanting the RV lead near septum and apex may lower DFTs [43][44][45]. Adding a shock coil in the middle cardiac vein [46][47][48][49][50] or azygous vein or implanting a subcutaneous array electrode [51][52][53][54] may be a more successful strategy for low DSM patients who failed to convert ventricular fibrillation with maximum delivered energy, especially in right-sided implant patients.…”
Section: Discussionmentioning
confidence: 99%
“…Satisfactory RV lead positioning is crucial to optimize DFTs. Rashba et al demonstrated that a very distal position of the coil in the RV was superior to a more proximal site in the body of the RV 2 . Thus positioning of the RV coil on the septum rather than at the apex may be disadvantageous to DFTs.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, ''optimal'' placement of the SVC coil is limited due to varying right heart dimension, and the fixed inter-coil spacing in current dual-coil defibrillation lead systems [47][48][49][50].…”
Section: Optimal Placement Of the Superior Vena Cava (Svc) Coil In Dumentioning
confidence: 99%