2013
DOI: 10.1016/j.ijleo.2012.09.038
|View full text |Cite
|
Sign up to set email alerts
|

Distortion correction using a single image based on projective invariability and separate model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 15 publications
0
2
0
1
Order By: Relevance
“…To better reflect the real image, geometric distortion calibration was performed. The Hough transformation method was used to find the four distortion calibration points of the rectangular calibration plate in the distorted image [18]. The system first found the outline of the rectangular calibration plate, and then used the approxPolyDP function to specify the precision to approximate the contour of the rectangular calibration plate, and fit the points on the contour of the rectangular calibration plate to four corner points.…”
Section: Methodsmentioning
confidence: 99%
“…To better reflect the real image, geometric distortion calibration was performed. The Hough transformation method was used to find the four distortion calibration points of the rectangular calibration plate in the distorted image [18]. The system first found the outline of the rectangular calibration plate, and then used the approxPolyDP function to specify the precision to approximate the contour of the rectangular calibration plate, and fit the points on the contour of the rectangular calibration plate to four corner points.…”
Section: Methodsmentioning
confidence: 99%
“…De forma geral, as distorções causadas pelos sistemas de lentes são maiores e comumente conhecidas como distorções radial simétrica e descentrada. Conforme Zhou et al (2013), estas distorções provêm de imperfeições no processo de fabricação e as correções são efetuadas mediante parâmetros calculados no processo de calibração (YANAGI; CHIKATSU, 2015)…”
Section: Transformação Para O Referencial Fotogramétrico Sem Distorçõesunclassified
“…In terms of researches on the image distortion correction, in 1966, the research results of CCD image distortion correction published by Hallert firstly adopt the least square method to realize the data processing [4]. In 1975, Faig considered various factors causing distortion during the CCD imaging, set up relatively sophisticated imaging model and solved by using the nonlinear optimization method [5].…”
Section: Introductionmentioning
confidence: 99%