2006
DOI: 10.1016/j.renene.2005.04.003
|View full text |Cite
|
Sign up to set email alerts
|

Distributed control system for frequency control in a isolated wind system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
41
0
3

Year Published

2007
2007
2019
2019

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 76 publications
(44 citation statements)
references
References 13 publications
0
41
0
3
Order By: Relevance
“…Ranjeva and Kulkarni [36] proposed selling excess energy generated by the hybrid systems back to the grid. Sebastian and Quesada [37] recommended using dump load to consume any excess energy generated by their analyzed hybrid systems dominated by wind turbine as a renewable source. The dump load used in [37] consists of eight threephase resistors connected in series, and gate turn-off thyristor switches are used to connect and disconnect these resistances.…”
Section: Framework and Suggestions To Utilize Excess Energy-a Reviewmentioning
confidence: 99%
“…Ranjeva and Kulkarni [36] proposed selling excess energy generated by the hybrid systems back to the grid. Sebastian and Quesada [37] recommended using dump load to consume any excess energy generated by their analyzed hybrid systems dominated by wind turbine as a renewable source. The dump load used in [37] consists of eight threephase resistors connected in series, and gate turn-off thyristor switches are used to connect and disconnect these resistances.…”
Section: Framework and Suggestions To Utilize Excess Energy-a Reviewmentioning
confidence: 99%
“…Studies presented in [18,19] modeled the battery energy storage as a DC voltage source in series with a current controlled inverter (CCI) in an islanded microgrid.…”
Section: DC Voltage Source In Series With a Resistormentioning
confidence: 99%
“…With the control strategy suggested in Section III for DFIG, the frequency of the system is made independent from the loading condition and rotor speed of the DFIG. Hence, the system frequency cannot be used for control coordination purposes as suggested in [12]. Also, it is said that if a remote power system consists of only static loads, it is difficult to identify the frequency deviation of the system using active power imbalance and the voltage deviation from reactive power imbalance.…”
Section: Controls Associated With Dfigmentioning
confidence: 99%
“…The operation of a hybrid power system consisting of an induction generator based wind turbine system, an inverter assisted battery storage unit and a dummy load is discussed in [12]. However, the standalone operation of a DFIG based RAPS system has not received much research attention when compared to its grid connected operation.…”
Section: Introductionmentioning
confidence: 99%