2014
DOI: 10.3182/20140824-6-za-1003.02116
|View full text |Cite
|
Sign up to set email alerts
|

Distributed Generation System Control Strategies in Microgrid Operation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 9 publications
0
10
0
1
Order By: Relevance
“…The PV array interfaces the grid through DC link and PWM inverter. The major role of the inverter is used for converting DC to AC power [15]. Generally the three phase inverter switching power devices consists of one, two or three arms.…”
Section: Inverter Operationmentioning
confidence: 99%
“…The PV array interfaces the grid through DC link and PWM inverter. The major role of the inverter is used for converting DC to AC power [15]. Generally the three phase inverter switching power devices consists of one, two or three arms.…”
Section: Inverter Operationmentioning
confidence: 99%
“…Microgrid capability to inject power to the grid while maintaining the system stability after getting disturbed is considered as one of the microgrid challenges [9,10]. Different control techniques such as active-reactive power control (PQ control), active power-voltage control (PV control) and voltage-frequency control (VF control) are utilized to control the DG units and achieve the required goals [11,12]. PQ scheme is used to control the exchanged real and reactive powers between the DG and grid [11].…”
Section: Introductionmentioning
confidence: 99%
“…Different control techniques such as active-reactive power control (PQ control), active power-voltage control (PV control) and voltage-frequency control (VF control) are utilized to control the DG units and achieve the required goals [11,12]. PQ scheme is used to control the exchanged real and reactive powers between the DG and grid [11]. Vf control is employed to keep the inverter voltage at constant value and return the frequency to its nominal value after getting real power disturbance [12].…”
Section: Introductionmentioning
confidence: 99%
“…Başka bir çalışmada, üç fazlı eviricinin kontrolünü sağlayan geleneksel aktif ve reaktif kontrolcü ve düşüm (droop) kontrolcünün performansları DÜ sistemlerinde karşılaştırılıp gerçekleştirilmiştir. Düşüm kontrolcünün daha güvenilir ve yüksek hızda cevap verdiği gözlemlenmiştir [7]. Diğer bir çalışmada ise PI ve PR kontrolcüleri için karşılaştırmalı çalışma yapılmıştır.…”
Section: Gi̇ri̇ş (Introduction)unclassified