2018
DOI: 10.1177/0040517518786272
|View full text |Cite
|
Sign up to set email alerts
|

Distribution of the preferred clothing pressure over the whole body

Abstract: A system for measuring clothing pressure employing a renewed hydrostatic pressure-balancing method was examined using three calibration methods. All methods revealed an almost perfectly linear Y = X relation for the pressure load (X) and the reading of the system (Y). In the application, the distributions of elastic band pressure were examined on 21 planes from head to foot. The preferred elastic band pressures of the leg and arm were significantly higher than those of the neck and abdomen. These results are d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 15 publications
0
6
0
Order By: Relevance
“…This was within the appropriate range (1-2 kPa) of the arm region. 35 As such, our study suggests that an elbow brace with multiple functions (i.e., heat and pressure) would be appropriate in terms of the human suitability and safety of healthy people. Furthermore, based on the results of this study, we intend to apply it to people with joint pain of various ages in the future.…”
Section: Discussionmentioning
confidence: 70%
See 3 more Smart Citations
“…This was within the appropriate range (1-2 kPa) of the arm region. 35 As such, our study suggests that an elbow brace with multiple functions (i.e., heat and pressure) would be appropriate in terms of the human suitability and safety of healthy people. Furthermore, based on the results of this study, we intend to apply it to people with joint pain of various ages in the future.…”
Section: Discussionmentioning
confidence: 70%
“…Appropriate P c at the arm differs from that at other body parts. 35,37 Thus, it is necessary to analyze the degree of bending and contraction of the SMA module associated with changing the number and size of knitted loops to produce modules suitable for the body part to which it is applied. Though we performed repeated actuating experiments on the simple actuator using the SMA to verify the continuity of the performance, in future work, we will verify durability by analyzing, for example, washing to increase usability.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Common methods include air pressure measurement, strain gauge sensors, garment pressure dummy testing, and virtual model testing. [53,57,[63][64][65] Fit comfort assessment requires a combination of subjective and objective tests to obtain valid results. Effective assessment of fit comfort requires the cooperation of subjective and objective tests.…”
Section: Fit Comfortmentioning
confidence: 99%