2012
DOI: 10.1080/15325008.2012.700381
|View full text |Cite
|
Sign up to set email alerts
|

Disturbances Rejection and Harmonics Reduction of Doubly Fed Induction Generator Based Wind Energy Conversion Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0
1

Year Published

2013
2013
2018
2018

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 33 publications
1
3
0
1
Order By: Relevance
“…8 b and d represent voltage harmonic pattern before and after harmonic elimination for 120° mode. Then the proposed switching was compared with the conventional switching demonstrated in [17] for the injected rotor voltage THD and the result is shown in Fig. 8 e , which also confirms the superiority of the proposed scheme.…”
Section: Simulation and Experimental Resultssupporting
confidence: 63%
See 2 more Smart Citations
“…8 b and d represent voltage harmonic pattern before and after harmonic elimination for 120° mode. Then the proposed switching was compared with the conventional switching demonstrated in [17] for the injected rotor voltage THD and the result is shown in Fig. 8 e , which also confirms the superiority of the proposed scheme.…”
Section: Simulation and Experimental Resultssupporting
confidence: 63%
“…viii. For each habitat, update the probability of its species count using (17) and compute each HSI. This is to indicate the best region for the biological species to survive.…”
Section: Proposed Harmonic Elimination Principle Using Bbo Algorithmmentioning
confidence: 99%
See 1 more Smart Citation
“…In another study, Amini [28], has minimized the special effects of the grid power quality problems on DFIG and power quality problems produced by the DFIG itself. To reach this aim, the ability of the grid-side converter is improved through adding an active filtering function based on the voltage-detecting scheme.…”
Section: Harmonicmentioning
confidence: 97%
“…As informações técnicas e datasheets das chaves estão disponíveis para a industrialização dos conversores eletrônicos de acordo com os relatórios técnicos disponíveis no ANEXO A. A aplicação das estratégias propostas significa uma quebra de paradigma para os sistemas de geração eólica na escala de MW, pois normalmente estes utilizam frequências de chaveamento dos conversores eletrônico reduzidas e inferiores a 5kHz como em [53], [48], [54], [42], devido ao aumento das perdas das chaves de potência no conversor eletrônico de silício.…”
Section: Simulações Em Software De Projeto De Conversor Eletrô-nicounclassified