2020
DOI: 10.1167/iovs.61.2.37
|View full text |Cite
|
Sign up to set email alerts
|

Diurnal Cycle of Translaminar Pressure in Nonhuman Primates Quantified With Continuous Wireless Telemetry

Abstract: PURPOSE. Recent retrospective clinical studies and animal experiments have suggested that cerebrospinal fluid pressure (CSFP) is important in glaucoma pathogenesis. Intraocular pressure (IOP) and CSFP are the driving components of the translaminar pressure (TLP), which directly effects the optic nerve head. This study measured the diurnal cycle of TLP using continuous wireless telemetry in nonhuman primates (NHPs), a common animal model of glaucoma. METHODS. We have developed an implantable wireless telemetry … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
32
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 21 publications
(34 citation statements)
references
References 38 publications
2
32
0
Order By: Relevance
“…1 ) based on a small piezoelectric transducer with low temporal drift that accurately measures IOP in the anterior chamber, ICP (as a surrogate for CSFP) in the parenchyma of the brain, and arterial blood pressure (BP) in the lumen of a major artery (BP data are not presented in this study). 37 An in-depth description of the surgical procedure and placement of both the wireless telemetry implant and pressure transducers was described in a recent study. 37 In brief, the IOP transducer was placed in the right eye and the ICP transducer was placed in the right frontal lobe, ∼2.5 cm from the midline of the brain at the same height as the IOP transducer when the animal is upright ( Fig.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…1 ) based on a small piezoelectric transducer with low temporal drift that accurately measures IOP in the anterior chamber, ICP (as a surrogate for CSFP) in the parenchyma of the brain, and arterial blood pressure (BP) in the lumen of a major artery (BP data are not presented in this study). 37 An in-depth description of the surgical procedure and placement of both the wireless telemetry implant and pressure transducers was described in a recent study. 37 In brief, the IOP transducer was placed in the right eye and the ICP transducer was placed in the right frontal lobe, ∼2.5 cm from the midline of the brain at the same height as the IOP transducer when the animal is upright ( Fig.…”
Section: Methodsmentioning
confidence: 99%
“… 37 An in-depth description of the surgical procedure and placement of both the wireless telemetry implant and pressure transducers was described in a recent study. 37 In brief, the IOP transducer was placed in the right eye and the ICP transducer was placed in the right frontal lobe, ∼2.5 cm from the midline of the brain at the same height as the IOP transducer when the animal is upright ( Fig. 1 ).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations