2015
DOI: 10.7860/jcdr/2015/15156.6661
|View full text |Cite
|
Sign up to set email alerts
|

Diurnal Variation in Peak Expiratory Flow and Forced Expiratory Volume

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
17
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(18 citation statements)
references
References 11 publications
1
17
0
Order By: Relevance
“…FEV1 is the volume which expired by the person in one second after a maximal inspiration. FEV1 reflects both small and larger airway function 10 and did not change much upon altitude induction 11 , which is also reflected in our study. FEV1/FVC ratio gives an index for airflow limitation 8 .…”
Section: Discussionsupporting
confidence: 82%
See 2 more Smart Citations
“…FEV1 is the volume which expired by the person in one second after a maximal inspiration. FEV1 reflects both small and larger airway function 10 and did not change much upon altitude induction 11 , which is also reflected in our study. FEV1/FVC ratio gives an index for airflow limitation 8 .…”
Section: Discussionsupporting
confidence: 82%
“…MEF 25 per cent is the flow rate when 25 per cent of FVC is remaining in the lungs and is an indicator of small airway function. MEF 75 per cent is the flow rate when 75 per cent of FVC is remaining and it reflects fairly large to medium size bronchi condition 10 . MEF 50 per cent is the flow rate when half of FVC is remaining and is indicative of small to medium airway function 10,18 .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The FEV1/FVC ratio is one of the well known markers of obstructive type of lung diseases [9]. FEF 25-75% flow rate is suggestive of anatomical region of mid-airway flow pathology [10]. In our study significant reduction in FEV1/FVC ratio and FEF 25-75% and no change in PEFR is suggestive of mild mid-airway obstruction after exposure to embalming fluid fumes.…”
Section: Rashmi Malhotra Et Al Embalming Fluid-a Poisonous Preservatmentioning
confidence: 46%
“…The subject was asked to take a mouthpiece in the sitting position, and to breathe in and out through the mouth using a nose plug. The forced vital capacity (FVC), forced expiratory volume in one second (FEV1), and maximal voluntary ventilation (MVV) were measured (Goel et al, 2015).…”
Section: Methodsmentioning
confidence: 99%