2015
DOI: 10.1007/s00264-015-2976-3
|View full text |Cite
|
Sign up to set email alerts
|

Does lateralisation of the centre of rotation in reverse shoulder arthroplasty avoid scapular notching? Clinical and radiological review of one hundred and forty cases with forty five months of follow-up

Abstract: Purpose Our purpose was to evaluate the influence of metallic lateralisation of the centre of rotation (COR) in reverse shoulder arthroplasty (RSA) on the incidence of scapular notching and its eventual clinical and radiological consequences. Methods We analysed 140 RSAs with a lateralised design (Arrow, FH Orthopedics, Mulhouse, France) implanted for massive rotator cuff tear with/without arthritis. Mean followup was 45 months (range 24-120, standard deviation 20). Patients were evaluated clinically using the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
48
0
2

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 95 publications
(52 citation statements)
references
References 44 publications
2
48
0
2
Order By: Relevance
“…With its characteristic reconstruction reversing the anatomical geometries of the glenohumeral joint, RSA allows for a decrease in pain and improvement of shoulder range of motion (ROM), especially elevation [ 3 , 4 ]. Despite its promising results, there exists a substantial variability regarding implant combination, leading to varied clinical outcomes after RSA [ 5 , 6 ]. Pre- and postoperative conditions of the deltoid muscle have been identified as key factors affecting surgical outcomes, as this muscle generates glenohumeral elevation solely after RSA [ 5 , 7 10 ].…”
Section: Introductionmentioning
confidence: 99%
“…With its characteristic reconstruction reversing the anatomical geometries of the glenohumeral joint, RSA allows for a decrease in pain and improvement of shoulder range of motion (ROM), especially elevation [ 3 , 4 ]. Despite its promising results, there exists a substantial variability regarding implant combination, leading to varied clinical outcomes after RSA [ 5 , 6 ]. Pre- and postoperative conditions of the deltoid muscle have been identified as key factors affecting surgical outcomes, as this muscle generates glenohumeral elevation solely after RSA [ 5 , 7 10 ].…”
Section: Introductionmentioning
confidence: 99%
“…All postoperative humeral fractures (50 cases of 3590) were associated with a traumatic event in 25 studies, resulting in 1.4% incidence. Twenty-nine cases (58%) were reported in press-fit stems, and one case of fracture of the greater tuberosity was included [ 35 ].…”
Section: Resultsmentioning
confidence: 99%
“…Rare complications included ten cases of unspecified glenoid/humeral disassembly; six humeral disassembly; two PE wear, both in two studies that considered two different generations of the Arrow Reverse [ 35 , 47 ], which were attributable to mechanical failure in the first-generation prostheses, successfully replaced in 2005; two cases of unspecified implant failure [ 39 ]; and two cases of pulmonary embolism (0.05%) [ 29 , 39 ].…”
Section: Resultsmentioning
confidence: 99%
“…34 Another study showed that notching was a problem in RTSAs performed for pseudoparalysis following MIRCT with concurrent arthritis compared with those without arthritis, with rates of 74% and 58% respectively. 36…”
Section: Resultsmentioning
confidence: 99%