Does the PillCam SB3 capsule endoscopy system improve image reading efficiency irrespective of experience? A pilot study

Abstract: Background and study aims  The aim of this study was tp compare the diagnostic efficiency of the PillCam SB3 capsule endoscopy (CE) system with the older system, PillCam SB2, taking into consideration the experience of the image reader. Patients and methods  Small intestinal CE was conducted on 64 patients around May 2014 when the SB3 was introduced in our hospital. Data obtained from 20 patients (SB2: 10 and SB3: 10) based on transit time were assessed by junior (experience: 20 images), intermediate (> 50), a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0
1

Year Published

2019
2019
2025
2025

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 15 publications
0
8
0
1
Order By: Relevance
“…24,25 In the current version of PillCam software (Rapid version 8.3), manual and automatic modes have been replaced by review mode, and Rapid version 8.3 enables more efficient video reading as compared with a previous version. 26 Previously, we reported that the reading time using automatic mode and quickview mode was significantly shorter than that in normal mode. 20 A previous version of SBI had low sensitivity for the detection of active bleeding, 24,25,27 and was upgraded using current PillCam software (Rapid version 8.3).…”
Section: Current Status Of Reading Software For Sbcementioning
confidence: 96%
See 1 more Smart Citation
“…24,25 In the current version of PillCam software (Rapid version 8.3), manual and automatic modes have been replaced by review mode, and Rapid version 8.3 enables more efficient video reading as compared with a previous version. 26 Previously, we reported that the reading time using automatic mode and quickview mode was significantly shorter than that in normal mode. 20 A previous version of SBI had low sensitivity for the detection of active bleeding, 24,25,27 and was upgraded using current PillCam software (Rapid version 8.3).…”
Section: Current Status Of Reading Software For Sbcementioning
confidence: 96%
“…The SBI mode functions by identifying red pixels on the screen, and then annotating the scroll bar automatically with a red line . In the current version of PillCam software (Rapid version 8.3), manual and automatic modes have been replaced by review mode, and Rapid version 8.3 enables more efficient video reading as compared with a previous version …”
Section: Current Status Of Reading Software For Sbcementioning
confidence: 99%
“…Capsule reviewers achieved an agreement rate of 70%, implying that just under a third of patients had different findings between the two models of capsule. In another study by Omori et al, 10 the use of the 3rd-generation PillCam® SB3 was found to reduce the time burden for both expert and inexperienced readers. The authors propose that this was due to an improved software algorithm for adaptive frame rate and improved image resolution.…”
Section: Discussionmentioning
confidence: 93%
“…The first-generation PillCam SB capsule endoscope measures 11 × 26 mm, and both the second and third generations have the same size (Figure 7) [31,32]. The PillCam SB capsule endoscope takes two pictures per second and has a viewing angle of 140 • .…”
Section: Upgrade Of a Capsule Endoscope Devicementioning
confidence: 99%