2011
DOI: 10.4103/1319-3767.74465
|View full text |Cite
|
Sign up to set email alerts
|

Doppler assessment of hepatic venous waves for predicting large varices in cirrhotic patients

Abstract: Background/Aim:Color Doppler examination of changes in hepatic venous waveforms is being evaluated as a means of prediction of severity of portal hypertension and presence of esophageal varices. Normal hepatic venous waveform shows a triphasic pattern. In cirrhosis, this pattern changes to a biphasic or monophasic pattern. We aimed to study the sensitivity of loss of normal hepatic venous waveforms in predicting large varices in a cross-sectional analysis.Materials and Methods:All patients, admitted or attendi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
12
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 12 publications
(16 citation statements)
references
References 22 publications
2
12
0
Order By: Relevance
“…Ultrasound parameters such as LS, SS, and spleen size have been widely investigated and reported to be reliable indicators of GEVs . Ultrasound methods are widely available and inexpensive but they are operator‐dependent and less sensitive, especially in obese patients.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Ultrasound parameters such as LS, SS, and spleen size have been widely investigated and reported to be reliable indicators of GEVs . Ultrasound methods are widely available and inexpensive but they are operator‐dependent and less sensitive, especially in obese patients.…”
Section: Discussionmentioning
confidence: 99%
“…In our opinion, MRE of the liver and spleen is welltolerated by almost all patients and should be implemented as part of a routine MRI examination. Ultrasound parameters such as LS, SS, and spleen size have been widely investigated and reported to be reliable indicators of GEVs (3)(4)(5)(6)(7)(8). Ultrasound methods are widely available and inexpensive but they are operator-dependent and less sensitive, especially in obese patients.…”
Section: Discussionmentioning
confidence: 99%
“…The classification of EV used by the authors of these studies was not homogenous and, therefore, it was difficult to compare the results; five studies used the 4 grades classification of EV [22][23][24][25][26], four used the 3 grades classification [8,[27][28][29], one study divided EV according to their size (small EV were considered those less than 5 mm while large EV had a size over 5 mm) [30] while one last study investigated only small EV according to the Beppu classification [31]. However, in the end, in order to increase the homogeneity of their final results, the same authors split the studied patients either in two groups (with EV vs. without EV or small EV vs. large EV) or in three groups (without EV vs. small EV vs. large EV).…”
Section: Gray-scale and Doppler Abdominal Ultrasound For Evaluation Omentioning
confidence: 99%
“…The measurements are relatively easy to perform and are associated with a less pronounced interobserver variability compared with other Doppler parameters. The study of Joseph T [30] performed on 51 patients with liver cirrhosis, of which 30 with small EV and 21 with large EV, has shown that the disappearance of the triphasic flow pattern had a high Se (95.23%) and negative predictive value (NPV) (95.23%) for the detection of large EV. However the positive predictive value (PPV) (42.6%) and Sp (10%) for this parameter were low and it ultimatelly failed to correlate accurately with the size of EV.…”
Section: Various Doppler Parameters Have Been Described For the Evalumentioning
confidence: 99%
See 1 more Smart Citation