2001
DOI: 10.2214/ajr.177.6.1771273
|View full text |Cite
|
Sign up to set email alerts
|

Dose and Pitch Relationship for a Particular Multislice CT Scanner

Abstract: The measured radiation dose to the phantom was identical for all pitch selections on the multislice helical CT system we tested. This unexpected result was because of an automatic proportionate increase in the tube current when the pitch selection was increased. Radiologists and physicists should exercise caution when extrapolating dose reduction strategies from single-slice to multislice helical CT systems, and they must acquire a detailed understanding of the multislice helical CT scanner of their chosen man… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
40
0
8

Year Published

2005
2005
2018
2018

Publication Types

Select...
5
3
2

Relationship

0
10

Authors

Journals

citations
Cited by 120 publications
(49 citation statements)
references
References 12 publications
1
40
0
8
Order By: Relevance
“…An automated exposure control system was switched on during all acquisitions (Care Dose 4D®; Siemens Medical Solutions) with a quality reference effective current-time product of 20 mAs. As defined by Mahesh et al, 14 effective tube current-time product corresponds to the tube current-time product divided by the pitch, whereby pitch is defined by Silverman et al 15 as the ratio between the table feed per rotation and the X-ray beam width. We used a dose modulation technique to reduce the radiation dose delivered to our volunteers and to abolish the effect of soft-tissue thickness of the chest wall in order to set lung attenuation measurements free of this thickness, including the influence of breasts (and their size) in females and not in males.…”
Section: Methods and Materials Subjectsmentioning
confidence: 99%
“…An automated exposure control system was switched on during all acquisitions (Care Dose 4D®; Siemens Medical Solutions) with a quality reference effective current-time product of 20 mAs. As defined by Mahesh et al, 14 effective tube current-time product corresponds to the tube current-time product divided by the pitch, whereby pitch is defined by Silverman et al 15 as the ratio between the table feed per rotation and the X-ray beam width. We used a dose modulation technique to reduce the radiation dose delivered to our volunteers and to abolish the effect of soft-tissue thickness of the chest wall in order to set lung attenuation measurements free of this thickness, including the influence of breasts (and their size) in females and not in males.…”
Section: Methods and Materials Subjectsmentioning
confidence: 99%
“…For each section position, the CT system calculates the average tube current, expressed as average effective mAs, throughout the duration of exposure. Effective mAs 18 are determined by dividing the product of milliamperes and rotation time by the pitch, which is the ratio between the table feed per rotation and the x-ray beam width or collimation. 19 The mean effective milliampere seconds of the whole examination are displayed at the scan console at the end of the examination and were recorded in our study.…”
Section: Ct Examinationsmentioning
confidence: 99%
“…The CTDIw was estimated from the values of beam collimation, kilovolts and effective mAs. [12]. The measurements of weighted CT dose indices were performed within a plastic body phantom of 32 cm in diameter (referred to as the CT dose index body phantom [13] of an average-sized man), provided by the CT scanner manufacturer (Siemens).…”
Section: Radiation Dose Estimationmentioning
confidence: 99%