2006
DOI: 10.1088/0031-9155/52/2/015
|View full text |Cite
|
Sign up to set email alerts
|

Dose distribution for endovascular brachytherapy using Ir-192 sources: comparison of Monte Carlo calculations with radiochromic film measurements

Abstract: An analysis of Ir-192 source distribution using the Monte Carlo method and radiochromic film experiments for endovascular brachytherapy is presented. Three different source possibilities, namely, mHDR Ir-192 sources with 5 mm and 2.5 mm step sizes and Ir-192 seed sources with 1 mm air gap are investigated to obtain uniform radial dose distribution throughout the treatment area. From this study, it is inferred that mHDR Ir-192 sources with 2.5 mm step size are effective for getting dose uniformity. Hence, diffe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2008
2008
2014
2014

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(1 citation statement)
references
References 27 publications
0
1
0
Order By: Relevance
“…In reviewing experimental dosimetric methods for brachytherapy, Perez-Calatayud et al (2012) commented that while radiochromic film dosimetry is a promising technique, it should be considered 'under development at this time' because of a number of artefacts, including non-uniformity, dose-rate dependence, film darkening kinetics and scanner artefacts. Radiochromic film has been used in brachytherapy dosimetry by many investigators over the last decade to make specific measurements or to verify Monte Carlo generated TG43based source model data (Chiu-Tsao et al 2006, Sureka et al 2007, Bonnet et al 2008, Hanley et al 2008, Kuo et al 2009, Hira et al 2010, Lliso et al 2011, Aldelaijan et al 2011, Uniyal et al 2012. However there have been no publications to date utilizing the latest Gafchromic EBT3 radiochromic film nor advanced film analysis techniques in brachytherapy.…”
Section: Introductionmentioning
confidence: 99%
“…In reviewing experimental dosimetric methods for brachytherapy, Perez-Calatayud et al (2012) commented that while radiochromic film dosimetry is a promising technique, it should be considered 'under development at this time' because of a number of artefacts, including non-uniformity, dose-rate dependence, film darkening kinetics and scanner artefacts. Radiochromic film has been used in brachytherapy dosimetry by many investigators over the last decade to make specific measurements or to verify Monte Carlo generated TG43based source model data (Chiu-Tsao et al 2006, Sureka et al 2007, Bonnet et al 2008, Hanley et al 2008, Kuo et al 2009, Hira et al 2010, Lliso et al 2011, Aldelaijan et al 2011, Uniyal et al 2012. However there have been no publications to date utilizing the latest Gafchromic EBT3 radiochromic film nor advanced film analysis techniques in brachytherapy.…”
Section: Introductionmentioning