Dose modeling in ultraviolet phototherapy

Abstract: This method could potentially serve as a basis for a full computational dose model for quantifying patient dose.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
25
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 21 publications
(28 citation statements)
references
References 18 publications
3
25
0
Order By: Relevance
“…20 It is also important to note that the penetration depth of UVR tends to be very shallow; at 311 nm, penetration is only 20-40 µm. 17,18 Radiometric terminology can vary greatly between various branches of optics, and in this work we shall use the convention laid down by Sliney, 14 where irradiance is defined as the power per unit area, and denoted E. The irradiance at a skin or detector surface is angle dependent 19 so surface orientation of a target site is an important factor to consider when estimating or measuring irradiance in practice. The most commonly encountered radiometric calculation in phototherapy relates prescribed dose D p to irradiance through…”
Section: Biological Effects Of Uvrmentioning
confidence: 99%
See 3 more Smart Citations
“…20 It is also important to note that the penetration depth of UVR tends to be very shallow; at 311 nm, penetration is only 20-40 µm. 17,18 Radiometric terminology can vary greatly between various branches of optics, and in this work we shall use the convention laid down by Sliney, 14 where irradiance is defined as the power per unit area, and denoted E. The irradiance at a skin or detector surface is angle dependent 19 so surface orientation of a target site is an important factor to consider when estimating or measuring irradiance in practice. The most commonly encountered radiometric calculation in phototherapy relates prescribed dose D p to irradiance through…”
Section: Biological Effects Of Uvrmentioning
confidence: 99%
“…As all UVR is incident and absorbed superficially by the skin, the orientation of the skin surface is of paramount importance if accurate dosimetry is to be achieved. A first principles model of UVR dose that factors in skin orientation was published in 2010, 19 which treats the UVR tube as a line source continuum of point sources. Figure 13(a) shows the vector convention used in such a formulation for a skin surface and Fig.…”
Section: E Comprehensive Dose Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…To this end, the authors have worked on characterizing tube emissions from the lamps 7 and reflector behavior. 8 These models describe the situation well for isolated cases, but it is important to test them in a clinical and nonidealized environment with existing cabins to ascertain their predictive power. This work focuses on narrow-band UVB sources centered around 311 nm which in recent years have shown great effectiveness in alleviating several skin complaints though the points discussed herein are of course still applicable to PUVA.…”
Section: Ultraviolet Phototherapy and Dose Modelingmentioning
confidence: 99%