2011
DOI: 10.1007/174_2011_451
|View full text |Cite
|
Sign up to set email alerts
|

Dose Optimization and Reduction in CT of the Brain and Head and Neck Region

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
5

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(9 citation statements)
references
References 65 publications
0
4
0
5
Order By: Relevance
“…Computed Tomography (CT) scanning with the ability to perform scans in a very short time alongside high image quality has become a common imaging modality in diagnostic radiology [1]. The use of this imaging modality dramatically has increased in recent years by the emergence of multidetector CT scanners (MDCT), about 12-fold in the UK and more than 20-fold in the USA in last 25 years [2].…”
Section: Introductionmentioning
confidence: 99%
“…Computed Tomography (CT) scanning with the ability to perform scans in a very short time alongside high image quality has become a common imaging modality in diagnostic radiology [1]. The use of this imaging modality dramatically has increased in recent years by the emergence of multidetector CT scanners (MDCT), about 12-fold in the UK and more than 20-fold in the USA in last 25 years [2].…”
Section: Introductionmentioning
confidence: 99%
“…Kualitas citra CT Scan dapat diukur dengan parameter seperti akurasi CT number, noise, Contrast to Noise Ratio (CNR), dan resolusi spasial. Dibanding dengan modalitas pencitraan lain, CT Scan memberikan radiasi dosis yang tinggi ke pasien, yang dapat memicu kanker [1,2] . Pemeriksaan rutin CT Scan thorax memberikan dosis 100 kali lebih besar dibanding pemeriksaan rutin thorax radiografi [3] .…”
Section: Abstrakunclassified
“…CT number merupakan angka yang menyatakan nilai koefisien atenuasi objek yang dicitrakan relatif terhadap koefisien atenuasi air, seperti pada persamaan 1. Nilai CT number bervariasi dari mulai 500-3000 HU untuk tulang, 0 untuk air, hingga -300 --800 untuk paru paru [2] . Evaluasi CT number dilakukan dengan memindai bagian modul homogen dari fantom yang terbuat dari bahan setara air.…”
Section: Gambar 1 Fantom Qa Ct Scanunclassified
“…The importance of CT dosimetry is due to the fact that the CT scan contributes to the main portion of the cumulative dose in many countries (about 67% in the US and 68% in the UK), as well as a growing number of CT exams (about 12-fold in the UK and more than 20-fold in the US [8,9]), after the introduction of multi-detector CT (MDCT) scanners that make CT scanning an easy and fast imaging modality and provide better image quality [10]. Also, in comparison to other X-ray-based imaging techniques, CT scan delivers a greater dose to patients [11]. For example, a routine chest CT scan delivers about 100 times (or higher) the dose relative to a routine chest conventional radiography [12].…”
Section: Introductionmentioning
confidence: 99%
“…Various local and national studies on CT dosimetry indicate that head and neck CT examinations are very common imaging protocols [17] and overall comprise about 25 to 30% of all CT procedures [8,11]. Pantos et al [18] reviewed 42 CT dosimetry publications and indicated the wide range (0.3-8.2 mSv) of the ED from head CT examinations.…”
Section: Introductionmentioning
confidence: 99%