Dose‐response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron‐produced monochromatic x‐ray beams

Abstract: EBT and EBT2 film sensitivity showed strong energy dependence over an energy range of 25 keV-4 MV, although this dependence becomes weaker for larger doses. EBT3 film shows weak energy dependence, indicating that it would be a better dosimeter for kV x-ray beams where beam hardening effects can result in large changes in the effective energy.

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
96
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 122 publications
(101 citation statements)
references
References 18 publications
4
96
0
1
Order By: Relevance
“…Brown et al 31 reported small energy dependence in low-energy monoenergetic photon beams (25-35 keV), whereas by contrast, Villarreal-Barajas and Khan 32 reported under-response of Figure 4. Set-up for the measurement of profiles and inspection of field sizes.…”
Section: Relative Dosimetry: Depth Dosesmentioning
confidence: 94%
“…Brown et al 31 reported small energy dependence in low-energy monoenergetic photon beams (25-35 keV), whereas by contrast, Villarreal-Barajas and Khan 32 reported under-response of Figure 4. Set-up for the measurement of profiles and inspection of field sizes.…”
Section: Relative Dosimetry: Depth Dosesmentioning
confidence: 94%
“…found an underresponse of relative sensitivity (defined as netOD xxkV /netOD 4MV ) ranging from 0.97 to 0.99 for monochromatic x rays of 25, 30, and 35 kV at varying dose levels (50–200 cGy) in a PMMA phantom 21. Masillon et al.…”
Section: Discussionmentioning
confidence: 99%
“…Wynikać to może z różnej serii zastosowanych filmów, skanera, jak i sposobu obróbki danych, zatem oparto się o rezultaty badań przeprowadzonych w tych samych warunkach. Według pracy Brown i Hongstrom [22] dla dawek do 3 Gy zdeponowanych przy użyciu promieniowania o energii 25keV -4MV film EBT wykazuje znaczną czułość na energię promieniowania, podczas gdy Chiu-Tsao [23] dla energii 21 keV -6 MV w zakresie dawek do 3 Gy wykazał, że odpowiedź filmów EBT jest niemalże niezależna od energii promieniowania, pogarszając się w zakresie bardzo niskich energii. Do podobnych wniosków dla zakresu energii 50 kVp -6 MV doszedł Butson [24].…”
Section: Kalibracja Filmów Dozymetrycznychunclassified