2011
DOI: 10.1016/j.radmeas.2011.03.031
|View full text |Cite
|
Sign up to set email alerts
|

Dose verification and calibration of the Cyberknife® by EPR/alanine dosimetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…As they are completely surrounded by ABS material to insure homogeneity of the environment, the dose measured in such conditions is an absorbed dose in alanine inside an ABS environment. To increase statistic quality, nine measurements are done for four irradiations durations (4,8,11, and 15 min). An absolute calibration implies a method allowing expressing results in terms of absorbed dose to water, inside a water environment, and in the TRS 398 reference conditions.…”
Section: B2 Dose Rate Verification With Alanine Dosimetermentioning
confidence: 99%
See 1 more Smart Citation
“…As they are completely surrounded by ABS material to insure homogeneity of the environment, the dose measured in such conditions is an absorbed dose in alanine inside an ABS environment. To increase statistic quality, nine measurements are done for four irradiations durations (4,8,11, and 15 min). An absolute calibration implies a method allowing expressing results in terms of absorbed dose to water, inside a water environment, and in the TRS 398 reference conditions.…”
Section: B2 Dose Rate Verification With Alanine Dosimetermentioning
confidence: 99%
“…[7][8][9][10] Moreover, the LNHB has already carried out such studies for innovative radiotherapy techniques like Cyberknife or Tomotherapy. 11,12 Thanks to the shape and dimensions of alanine dosimeters, they can be used for small beams. Alanine dosimeters have interesting advantages: measures are at solid state and nondestructive, their responses are almost independent on the dose rate and energy of radiotherapy photon beams and their signal is stable in time (signal decreases less than 1% per year).…”
Section: Introductionmentioning
confidence: 99%
“…[ 31 93 94 ] Recently, alanine has been used to verify advanced radiotherapy techniques such as IMRT and radiosurgery. [ 95 96 ]…”
Section: Various Dosimeters Used In Small-field Dosimetrymentioning
confidence: 99%
“…with doses lower than 10 Gy. In recent years, advanced therapy modalities such as the cyberknife have also been checked using alanine dosimetry [8]. Within the framework of a quality assurance project in Belgium, a large fraction of the Belgian therapy centres participated in a dosimetry audit using alanine/ESR between 2009 and 2011 [9].…”
Section: Introductionmentioning
confidence: 99%