Dosimeter Gel and MR Imaging for Verification of Calculated Dose Distributions in Clinical Radiation Therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0

Year Published

1998
1998
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(15 citation statements)
references
References 29 publications
0
15
0
Order By: Relevance
“…An alternative approach would be to use gel dosimeters 19 , 20 , 21 . Dosimetric cryogels are flexible materials that conform easily to curved regions of the body.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…An alternative approach would be to use gel dosimeters 19 , 20 , 21 . Dosimetric cryogels are flexible materials that conform easily to curved regions of the body.…”
Section: Introductionmentioning
confidence: 99%
“…In regions where the surface dose is of interest, a dosimetric cryogel may provide an accurate estimation of superficial dose distributions. Cryogels may also be used to quantify uncertainties in setup or field conjunctioning, and breathing irregularities during left breast or chest wall DIBH radiation therapy 20 , 21 …”
Section: Introductionmentioning
confidence: 99%
“…Karger et al (1999) used an array of up to 24 pinpoint ionization chambers for 3D dose verification. Gel and radiochromic dosimeters can be used to reconstruct high-resolution 3D dose distributions for proton beams (Johansson et al , 1997; Zhao et al , 2012). However, dosimetric gels can be difficult to work with, requiring careful preparation and handling procedures.…”
Section: Introductionmentioning
confidence: 99%
“…matrix resulting from subtracting the calculated dose matrix from the FeMRI measured dose matrix could also be used to evaluate the application. For visualization purposes, the deviation matrix could be coded using a colour scale (5).…”
Section: Resultsmentioning
confidence: 99%
“…The deviations could have different origins, as shortcomings of both detector and TPS system. Deviations can be enhanced or cancelled, particularly if several treatment beams are superimposed (5). Hence, before setting up complex treatment techniques using FeMRI, it is very important to investigate the dosimetry system in simple and well-defined radiation beams.…”
Section: Resultsmentioning
confidence: 99%