2020
DOI: 10.21203/rs.3.rs-58107/v1
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Dosimetric comparison between helical tomotherapy, volume modulated arc-therapy and Fixed-Field intensity modulated radiation therapy in postoperative adjuvant radiotherapy for cervical cancer

Abstract: Background: To evaluate the dosimetric parameters among three different radiotherapy techniques in patients with postoperative cervical cancer, including the Helical Tomotherapy (HT), the Volume Modulated Arc-Therapy (VMAT), and the Fixed-Field intensity modulated radiation therapy (FF-IMRT). Methods: Fifteen cervical cancer patients treated with postoperative radiotherapy were re-planning with HT, VMAT and FF-IMRT. The prescribed target dose of the patients was 1.8/45Gy. The paired-samples t-test was used to … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
7
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(10 citation statements)
references
References 24 publications
3
7
0
Order By: Relevance
“…Also, our results showing that VMAT can deliver dose in a shorter time than HT is in agreement with the other studies. 10,11,13,15 Furthermore, our finding that plan computation times for VMAT are longer than those for HT is consistent with the literature 48 and is explained because, mathematically speaking, HT is an easier optimization problem than VMAT. 42,43 Finally, a previous study on 3 patients suggested that the distance between Pareto fronts for different treatment techniques was related to the relative PTV-rectum-overlap volume.…”
Section: Discussionsupporting
confidence: 90%
See 4 more Smart Citations
“…Also, our results showing that VMAT can deliver dose in a shorter time than HT is in agreement with the other studies. 10,11,13,15 Furthermore, our finding that plan computation times for VMAT are longer than those for HT is consistent with the literature 48 and is explained because, mathematically speaking, HT is an easier optimization problem than VMAT. 42,43 Finally, a previous study on 3 patients suggested that the distance between Pareto fronts for different treatment techniques was related to the relative PTV-rectum-overlap volume.…”
Section: Discussionsupporting
confidence: 90%
“…This finding is in agreement with studies that were in favor of VMAT for simple geometries 15,16 and showed that HT was superior for complex geometries. 12,13 The reason why older studies were never in favor of VMAT, even for simple geometries, is the following: 10,11,14,[44][45][46] VMAT is a difficult, non-convex optimization problem that requires sophisticated optimization algorithms to avoid getting trapped in a local optimum far away from the global optimum. 42,43,47 With the development of new algorithms and faster computers, one may expect VMAT to get better over years.This is not the case for HT,because it is an easier convex optimization problem.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations