2012
DOI: 10.1016/j.meddos.2011.10.001
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
14
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(16 citation statements)
references
References 37 publications
2
14
0
Order By: Relevance
“…1316 These studies were performed for conventionally fractionated radiation regimens and were designed to address the efficacy of VMAT in comparison with standard 5-field IMRT. Eppinga and colleagues reported improved CI with VMAT treatment, reduced dose to OARs, and decreased treatment delivery times.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…1316 These studies were performed for conventionally fractionated radiation regimens and were designed to address the efficacy of VMAT in comparison with standard 5-field IMRT. Eppinga and colleagues reported improved CI with VMAT treatment, reduced dose to OARs, and decreased treatment delivery times.…”
Section: Discussionmentioning
confidence: 99%
“…Although this technique has been studied in many anatomical sites, 4 relatively recent studies have specifically addressed utilization of VMAT in the treatment of pancreatic cancer. 1316 Eppinga et al . published a series of 10 cases assessing the delivery of VMAT as an alternative to standard 5-field IMRT in advanced pancreatic cancer.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…8 In addition to better conformity, journal homepage: www.meddos.org VMAT was proven to have lesser monitor units and shorter treatment time. 9,10 Organs, e.g., liver, small bowel, spinal cord, and bilateral kidneys, were also shown to have similar or better dosimetric results with VMAT over IMRT, as well as 3D-CRT. 11 Because VMAT delivers radiation beams continuously in a complete gantry rotation, patients are exposed to low dose spillage in a large region outside of the intended target.…”
Section: Introductionmentioning
confidence: 92%
“…Similar to our study design, Ali et al, analyzed 10 patients' dosimetric data and concluded that using double arc VMAT for curative or adjuvant radiotherapy for pancreas cancer patients, provides lower mean and V20-V15 doses of both kidney compared to IMRT, but other organ doses of both plans were found to be similar. [22] This gain for bilateral kidneys was ranging from 14%-75%. In another similar dosimetric study for evaluating the use of double arc VMAT for locally advanced pancreas tumors, reduced monitor units, bilateral kidney V15 dose, mean dose of liver, stomach and small bowel dose reported.…”
Section: Disclosure Statementmentioning
confidence: 98%