2012
DOI: 10.1016/j.ijrobp.2011.12.001
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric Impact of Breathing Motion in Lung Stereotactic Body Radiotherapy Treatment Using Image-Modulated Radiotherapy and Volumetric Modulated Arc Therapy

et al.
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

8
109
1

Year Published

2013
2013
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 119 publications
(129 citation statements)
references
References 18 publications
8
109
1
Order By: Relevance
“…This effect has been studied in only two publications for tangential fields techniques39, 40 but not for VMAT for breast. However, the interplay effect has been largely studied in the case of lung RT41, 42, 43, 44, 45, 46 with motion amplitude being largely superior to those encountered in breast treatment. Those studies show that the interplay effect generates a blurring effect on the dose distribution.…”
Section: Discussionmentioning
confidence: 99%
“…This effect has been studied in only two publications for tangential fields techniques39, 40 but not for VMAT for breast. However, the interplay effect has been largely studied in the case of lung RT41, 42, 43, 44, 45, 46 with motion amplitude being largely superior to those encountered in breast treatment. Those studies show that the interplay effect generates a blurring effect on the dose distribution.…”
Section: Discussionmentioning
confidence: 99%
“…Besides, organ motion has become an important consideration for SBRT treatment planning for tumors in the thorax, abdomen and prostate that are known to move with breathing motion. 10 The management of motion control is established with the setup of motion encompassing methods such as respiratory gated imaging, breath hold technique, forced shallow breathing with abdominal compression, etc. Also, a stringent tolerance limit is required in MLC leaf position to deliver the dose in small and highly complex apertures created by the VMAT optimization.…”
Section: Introductionmentioning
confidence: 99%
“…The use of daily localization with CBCT could detect changes in the target and ensure the safety of OARs 34. As the spatial distribution of biological properties in tumors such as proliferation and hypoxia are known to be nonuniform, the dose distribution that maximizes tumor control probability for a given tumor is also nonuniform.…”
Section: Discussionmentioning