1995
DOI: 10.1016/0360-3016(95)00114-3
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric properties of megavoltage grid therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
45
1

Year Published

1996
1996
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 46 publications
(50 citation statements)
references
References 8 publications
4
45
1
Order By: Relevance
“…Whereas the low-dose bystander effect in a biological system is of relevance to carcinogenesis and could have serious implications for radiation risk assessment, the bystander signaling induced by a high dose has therapeutic implications. High-dose RIBEs could be the underlying mechanism involved in a novel treatment modality, such as high-dose spatially fractionated radiation GRID therapy for management of advanced cancers (33)(34)(35)(36)(37). Significant induction of LDL-enriched ceramide, secretory SMase, and TNF-a in serum from patients treated with spatially fractionated Figure 5.…”
Section: Discussionmentioning
confidence: 99%
“…Whereas the low-dose bystander effect in a biological system is of relevance to carcinogenesis and could have serious implications for radiation risk assessment, the bystander signaling induced by a high dose has therapeutic implications. High-dose RIBEs could be the underlying mechanism involved in a novel treatment modality, such as high-dose spatially fractionated radiation GRID therapy for management of advanced cancers (33)(34)(35)(36)(37). Significant induction of LDL-enriched ceramide, secretory SMase, and TNF-a in serum from patients treated with spatially fractionated Figure 5.…”
Section: Discussionmentioning
confidence: 99%
“…The dose distributions of grid block with hole diameters of 0.5 cm, 0.75 cm, 1.0 cm, 1.25 cm, and 1.5 cm with constant center‐to‐center spacing of 1.8 cm, were calculated separately using the Monte Carlo simulation technique. Since the prescription dose of 15 Gy per fraction in megavoltage grid therapy is widely accepted, 9 , 10 , 19 , 29 this dose was considered in comparison of the TR values for different grid blocks. Equivalent uniform dose (EUD) for a grid with hole diameter of 1.0 cm and center‐to‐center distance of 1.8 cm was calculated.…”
Section: Methodsmentioning
confidence: 99%
“…Spatially fractionated radiotherapy (GRID) is a technique of irradiation that has been used successfully for the curative or palliative treatment of bulky tumors $6 cm (3)(4)(5). Irradiation is delivered through a specially made grid collimator or by using a multileaf collimator (MLC) as a grid field shaper (3,(6)(7)(8). In GRID therapy the target volume does not receive a homogeneous dose of radiation.…”
Section: Introductionmentioning
confidence: 99%