2006
DOI: 10.1016/j.radonc.2006.10.020
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning

Abstract: Published paper

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
45
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 68 publications
(48 citation statements)
references
References 25 publications
3
45
0
Order By: Relevance
“…All calculated doses agreed with measurement to within 3% or 3.3mm distance to agreement and all but one to within 3% or 3mm, confirming the accuracy of the AAA calculations of these IMRT plans. The magnitudes of the mean discrepancies were of the same order as were found in a previous study for conventional radiotherapy treatment fields measured on the thorax phantom [9] and as those reported for IMRT fields by Khodri et al [28].…”
Section: Discussionsupporting
confidence: 85%
See 1 more Smart Citation
“…All calculated doses agreed with measurement to within 3% or 3.3mm distance to agreement and all but one to within 3% or 3mm, confirming the accuracy of the AAA calculations of these IMRT plans. The magnitudes of the mean discrepancies were of the same order as were found in a previous study for conventional radiotherapy treatment fields measured on the thorax phantom [9] and as those reported for IMRT fields by Khodri et al [28].…”
Section: Discussionsupporting
confidence: 85%
“…The improved accuracy of the AAA in phantom situations and 3D conformal radiotherapy (3D-CRT) treatment plans compared to Eclipse's Pencil Beam Convolution (PBC) algorithm (the Eclipse implementation of the Single Pencil Beam algorithm of the same manufacturer's CadPlan TPS) has been reported by several authors [8][9][10][11][12].…”
Section: Introductionmentioning
confidence: 99%
“…This large hollow structure could pose a challenge for the model‐based dose calculation algorithm implemented in the treatment planning system (TPS). ( 14 – 17 ) To evaluate this issue, we perform an open field dose validation for both the ArcCHECK system and the TPS. Considering the uncertainties of the diode dose measurement and the TPS dose calculation, Monte Carlo (MC) simulation, which has been recognized as the gold standard for estimating the radiotherapy dose measurements/calculations, ( 18 ) is utilized as an independent reference in this study.…”
Section: Introductionmentioning
confidence: 99%
“…( 8 14 ) For dose distribution calculations in heterogeneous media, and especially at interfaces, the AAA algorithm has been shown to be consistently more accurate than the pencil beam convolution (PBC) algorithm. ( 9 , 10 , 14 16 ) …”
Section: Introductionmentioning
confidence: 99%