2021
DOI: 10.1016/j.apradiso.2020.109451
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetry of tumor targeting imaging by convergent X-ray beam as compared with nuclear medicine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…The scope of the OXIRIS project, as reported in this work, is to overcome such limitations attaining SNR improvements when targeting tumors by GNP fluorescence implementing a convergent X-ray beam coupled to a confocal EDXRF detection system with the remarkable advantage of mapping by exciting the K-lines of the high atomic number elements, like gold nanoparticles. Previous works [49][50][51] have demonstrated the feasibility of the technique here proposed. Furthermore, aimed at validating the methodology along with prototype design, dedicated Monte Carlo simulation tools 52,53 have been developed and implemented.…”
Section: Introductionmentioning
confidence: 77%
See 3 more Smart Citations
“…The scope of the OXIRIS project, as reported in this work, is to overcome such limitations attaining SNR improvements when targeting tumors by GNP fluorescence implementing a convergent X-ray beam coupled to a confocal EDXRF detection system with the remarkable advantage of mapping by exciting the K-lines of the high atomic number elements, like gold nanoparticles. Previous works [49][50][51] have demonstrated the feasibility of the technique here proposed. Furthermore, aimed at validating the methodology along with prototype design, dedicated Monte Carlo simulation tools 52,53 have been developed and implemented.…”
Section: Introductionmentioning
confidence: 77%
“…The effective distance from the X-ray source to F I G U R E 2 Dynamic (left) and static (right) configurations for orthovoltage X-ray convergent beam devices. 51 C-arc support for rotation (1), the X-ray tube (2), counterweight (3), dynamic convergent cone (4), dynamic focus (5), cathode electron gun (6), cylindrical anode and shield (7), collimator outlet holes (8), brake and shield (9), and static device focus (10) [Colour figure can be viewed at wileyonlinelibrary.com] the system geometrical focus is 150 mm. Finally, a hollow confocal spherical phantom was considered, made of ABS material, 0.8 mm thick and 10 cm in diameter, filled with water.…”
Section: Methodology and Prototype Designmentioning
confidence: 99%
See 2 more Smart Citations