2021
DOI: 10.1088/1361-6595/ac12d9
|View full text |Cite
|
Sign up to set email alerts
|

DPEx-II: a new dusty plasma device capable of producing large sized DC coulomb crystals

Abstract: The creation of a spatially extended stable DC complex plasma crystal is a big experimental challenge and a topical area of research in the field of dusty plasmas. In this paper we describe a newly built and commissioned dusty plasma experimental (DPEx-II) device at the Institute for Plasma Research. The device can support the formation of large sized Coulomb crystals in a DC glow discharge plasma. The plasma in this L-shaped table-top glass chamber is produced between a circular anode and a long tray shaped c… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 58 publications
1
13
0
Order By: Relevance
“…The ∆z distribution essentially implies that the particles indeed form a bilayer system at V = 400 V with the two distinct peaks in Fig. 3 The unique electrode configuration [26] used in our DC discharge has the effect of moderating the dust-wake interaction. This configuration allows the ions to move towards the cathode with a higher Mach number (M) and leads to a weaker wake potential as compared to those commonly found in RF discharges [32][33][34].…”
Section: Resultsmentioning
confidence: 87%
See 3 more Smart Citations
“…The ∆z distribution essentially implies that the particles indeed form a bilayer system at V = 400 V with the two distinct peaks in Fig. 3 The unique electrode configuration [26] used in our DC discharge has the effect of moderating the dust-wake interaction. This configuration allows the ions to move towards the cathode with a higher Mach number (M) and leads to a weaker wake potential as compared to those commonly found in RF discharges [32][33][34].…”
Section: Resultsmentioning
confidence: 87%
“…In this condition, the resistance of the potentiometer is set at 3 kΩ. The plasma parameters such as plasma density and electron temperature, obtained from single and a double Langmuir probe measurements, are in the range of 1 − 2 x 10 15 /m 3 and 2 − 3 eV, respectively, for our discharge conditions [26]. The confinement strength is altered by adjusting the discharge voltage (V) and keeping the gas pressure (P) constant.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Experimental set-up. All the experiments presented in this work have been performed in the Dusty Plasma Experimental-II (DPEx-II) device 42 , which has an L-shaped vacuum vessel made of pyrex-glass consisting of two chambers as shown in Fig. 1a.…”
Section: Phase Coexistence Experiments In Complex Plasmasmentioning
confidence: 99%