2018
DOI: 10.1016/j.ultras.2017.10.001
|View full text |Cite
|
Sign up to set email alerts
|

Droplet size prediction in ultrasonic nebulization for non-oxide ceramic powder synthesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 23 publications
0
3
0
1
Order By: Relevance
“…The atomized droplets play the role of “seed particles” and form an aggregation nucleus in the aerosol that can effectively collide with the surrounding fine particles to improve the aggregation efficiency. After the disinfectant is atomized, a large amount of water vapor is emitted in the air to increase the indoor relative humidity, improve the penetrating ability of the disinfectant on the bacterial wall, enhance the disinfection effect, and reduce the disinfection time ( Muñoz et al, 2017 ).…”
Section: Introductionmentioning
confidence: 99%
“…The atomized droplets play the role of “seed particles” and form an aggregation nucleus in the aerosol that can effectively collide with the surrounding fine particles to improve the aggregation efficiency. After the disinfectant is atomized, a large amount of water vapor is emitted in the air to increase the indoor relative humidity, improve the penetrating ability of the disinfectant on the bacterial wall, enhance the disinfection effect, and reduce the disinfection time ( Muñoz et al, 2017 ).…”
Section: Introductionmentioning
confidence: 99%
“…Particle size is extremely important for the nebulization of liquid drugs. In comparison, the water particles atomized by the five types of LN devices were smaller than those generated by typical PZT devices, which produced water particles with a diameter of around 7 µm [31] , [32] . Furthermore, to compare studies with the PZT and LN, the materials of the atomization device, the driving frequency, the particle peak size, solutions and the vibration mode are summarized ( Table 1 ) [33] , [34] , [35] , [36] .…”
Section: Resultsmentioning
confidence: 80%
“…Ramisetty et al (2013) proposed a correlation for the Sauter mean diameter using experimental data from aqueous glycerine and aqueous methanol solutions [8]. Muñoz et al (2018) modified Rajan and Pandit's dimensionless numbers and fitted a correlation for the number mean diameter of an aqueous methanol solution [9]. In this paper, correlations to estimate the number, surface, volume, and Sauter mean diameter are fitted.…”
Section: Introductionmentioning
confidence: 99%