The sliding wear behaviour of newly developed ferrous powder metallurgy samples was investigated under dry sliding conditions. Wear tests were conducted by varying the normal loads of 30 N, 40 N, and 50 N at a constant velocity of 1 m/s and then at a constant load of 30 N by varying the sliding velocities by 0.5 m/s, 1 m/s, and 2 m/s at room temperature. Furthermore, the variations in the wear rate and coefficient of friction at a constant sliding distance of 5400 m were studied at different normal loads keeping sliding velocity constant at 1 m/s as well as at different sliding velocities and maintaining normal load at 30N. The wear characteristics were evaluated using weight loss measurements. The mechanism of wear was observed using scanning electron microscope and compositional analysis using energy-dispersive X-ray spectroscopy (EDX). It was found that increased normal load had a dominant effect on the wear loss in comparison to increased sliding speed during the tribological testing of the powder metallurgy samples.