2016
DOI: 10.1109/tie.2016.2548999
|View full text |Cite
|
Sign up to set email alerts
|

Dual Converter Fed Open-End Transformer Topology with Parallel Converters and Integrated Magnetics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 26 publications
0
8
0
Order By: Relevance
“…The above analysis suggests that the special working characteristic (the harmonic cancellation characteristic) of the DI-OEWT topology should be considered when designing the filter. The "common capacitor type filter" (here we call it "Type-2 filter") for DI-OEWT topology, which is presented in [21,22], seems to be a reasonable one, as illustrated in Figure 7. Two inverters are connected to a common shunt capacitor branch of the filter through the two inverter-side inductors, respectively.…”
Section: Type-2 Filter For the Di-oewt Topologymentioning
confidence: 98%
See 3 more Smart Citations
“…The above analysis suggests that the special working characteristic (the harmonic cancellation characteristic) of the DI-OEWT topology should be considered when designing the filter. The "common capacitor type filter" (here we call it "Type-2 filter") for DI-OEWT topology, which is presented in [21,22], seems to be a reasonable one, as illustrated in Figure 7. Two inverters are connected to a common shunt capacitor branch of the filter through the two inverter-side inductors, respectively.…”
Section: Type-2 Filter For the Di-oewt Topologymentioning
confidence: 98%
“…It is uneconomic to reduce this voltage because that will increase the system installation costs and narrow the maximum power point tracking (MPPT) voltage operation range [2]. In addition, it will be better for the dual-inverter to be supplied by two separate arrays (two DC sources), which can not only achieve multiple MPPTs, but also suppress the circulating current among the two inverters [21,22]. The fault tolerance capability cannot be a special advantage of the dual-inverter because the multi-parallel inverter topology has the same capability as well.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The open-end operation of transformers was previously studied in [23], in which an inductor was integrated into the open-end transformer to limit the circulating current between parallel connected converters. Gohil et al [24] designed an LCL filter for the harmonic cancelation of the open-end transformer proposed in [23].…”
Section: Introductionmentioning
confidence: 99%