2019
DOI: 10.1007/s11547-019-01107-8
|View full text |Cite
|
Sign up to set email alerts
|

Dual-energy CT: theoretical principles and clinical applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
110
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 92 publications
(110 citation statements)
references
References 63 publications
0
110
0
Order By: Relevance
“…In another study (36) the sensitivity for IPSS was 82% while it was 48% for the high dose dexamethasone test and 70% for the CRH test. When compared with other imaging modalities, IPSS showed a high accuracy: in a study performed on 54 patients (37) the accuracy of IPSS was 88% while the accuracy of MRI was 54%; in another study where 84 patients were enrolled, the sensitivity was 40% for CT (38,39), 50% for MRI and 90% for IPSS (40).The diagnostic accuracy of MRI in differentiating central and ectopic Cushing's syndrome was found to be 58% while the accuracy of IPSS was found to be 100% (35). Several studies showed, however, that the diagnostic accuracy is not absolute and both false-negatives (lack of a central/ peripheral gradient in patients with CD) and false positives (presence of a central/peripheral gradient in patients with ectopic ACTH secretion) occur.…”
Section: Inferior Petrosal Sinus Sampling and Its Rule In The Diagnostic Workupmentioning
confidence: 99%
“…In another study (36) the sensitivity for IPSS was 82% while it was 48% for the high dose dexamethasone test and 70% for the CRH test. When compared with other imaging modalities, IPSS showed a high accuracy: in a study performed on 54 patients (37) the accuracy of IPSS was 88% while the accuracy of MRI was 54%; in another study where 84 patients were enrolled, the sensitivity was 40% for CT (38,39), 50% for MRI and 90% for IPSS (40).The diagnostic accuracy of MRI in differentiating central and ectopic Cushing's syndrome was found to be 58% while the accuracy of IPSS was found to be 100% (35). Several studies showed, however, that the diagnostic accuracy is not absolute and both false-negatives (lack of a central/ peripheral gradient in patients with CD) and false positives (presence of a central/peripheral gradient in patients with ectopic ACTH secretion) occur.…”
Section: Inferior Petrosal Sinus Sampling and Its Rule In The Diagnostic Workupmentioning
confidence: 99%
“…Recent technological advances in head and neck imaging, including facial and oral imaging, and in particular SGs imaging, allowed to improve the multimodality study of this challenging anatomical region (4)(5)(6)(7)(8)(9)(10)(11)(12). The following step is to integrate patients' clinical and histopathology data with imaging biomarkers with the ultimate aim of using imaging biomarkers as decision-support tools to improve pSS diagnostic process and patients' stratification in clinical practice.…”
Section: Introductionmentioning
confidence: 99%
“…The terms dual-energy CT (DECT) refers to the acquisition of CT attenuation data deriving from two photon energies, in this way the attenuation differences between various materials could provide their characterization (1)(2)(3)(4). Despite the fact that the role of DECT in diagnostic imaging was described in the late 1970, only in the last years, thanks to the emerging technologies, it has become possible to perform two acquisitions almost simultaneously at different tube voltage, avoiding misregistration artefacts between the two imaging sets (5,6).…”
Section: Introductionmentioning
confidence: 99%