Abstract: Combined implantation of an add-on diffractive sulcus IOL and a monofocal capsular bag IOL was safe and effective in improving far and near visual acuity in cataract surgery. Preliminary visual acuity results were similar to those in eyes with a single 1-piece diffractive multifocal IOL.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
27
0
8

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(46 citation statements)
references
References 39 publications
1
27
0
8
Order By: Relevance
“…[1][2][3][4] To our knowledge, this clinical case represents the first implantation of a combined toric diffractive-additive IOL. It shows that the addition of a cylinder correction to a multifocal optic is also possible in additive IOLs, which increases the number of selectable patients for additive IOL implantation.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[1][2][3][4] To our knowledge, this clinical case represents the first implantation of a combined toric diffractive-additive IOL. It shows that the addition of a cylinder correction to a multifocal optic is also possible in additive IOLs, which increases the number of selectable patients for additive IOL implantation.…”
Section: Discussionmentioning
confidence: 99%
“…They can be implanted in the sulcus of pseudophakic eyes to correct residual refractive errors after cataract or refractive surgery and are also a good option in cases of dynamic refraction changes since they can be easily explanted or exchanged. [1][2][3][4] The convex-concave optic shape of these IOLs prevents contact with the primary IOL in the capsular bag.…”
mentioning
confidence: 99%
“…Add-on IOLs are now available not only to correct spherical errors but also to correct astigmatism using toric designs and to provide near visual acuity without glasses using multifocal designs. [12][13][14] These IOLs have become part of refractive surgery and are accompanied by high patient expectations. To meet these expectations, correct IOL power calculation, IOL rotational stability, and a predictable IOL position without unexpected vault are necessary.…”
Section: J Cataract Refract Surg 2012; 38:986-991 Q 2012 Ascrs and Escrsmentioning
confidence: 99%
“…В ряде работ показана вероятность развития пигментной глау-комы (синдрома пигментной дисперсии) после имплан-тации «piggyback» ИОЛ с плоским профилем [17,18]. В связи с возможностью появления интерленти-кулярных помутнений были разработаны и внедрены специальные модели ИОЛ, так называемые сулькусные ИОЛ (производители -фирмы Rayner и Zeiss) [19]. Из-начально сулькусные ИОЛ были только асферическими, но в настоящее время известны торические, мультифо-кальные и мультифокальные торические сулькусные ИОЛ [20,21].…”
Section: имплантация «Piggyback» иол или замена иол?unclassified