Dual‐labeled chemiluminescence enzyme immunoassay for simultaneous measurement of total prostate specific antigen (TPSA) and free prostate specific antigen (FPSA)

Abstract: The specificity for early diagnostic of prostate-specific antigen (PSA) is low because the current technology mostly allows the detection of only one biomarker at one time. In this work, a dual- The proposed method presented the sensitivity of 0.03 ng ml −1 and 0.05 ng ml −1 for FPSA and TPSA respectively, with low cross-reactivities. Compared with the results from commercial chemiluminescent kits there was good correlation, indicating that this established method could be used to simultaneously to measure the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
9
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(10 citation statements)
references
References 33 publications
1
9
0
Order By: Relevance
“…Laboratory examinations were done in the Second Hospital of Shandong University with a biochemical analyzer which is hisemikon blood cell instrument XN9000 (Roche, Basel, Switzerland). The serum PSA was measured using an automatic electrochemistry luminescence immunoassay system (CLEIA) (Roche, Basel, Switzerland) ( 18 ). Complete blood count analysis was performed immediately within half an hour after collection of blood samples into EDTA tube after venipuncture to prevent platelet activation in vitro .…”
Section: Methodsmentioning
confidence: 99%
“…Laboratory examinations were done in the Second Hospital of Shandong University with a biochemical analyzer which is hisemikon blood cell instrument XN9000 (Roche, Basel, Switzerland). The serum PSA was measured using an automatic electrochemistry luminescence immunoassay system (CLEIA) (Roche, Basel, Switzerland) ( 18 ). Complete blood count analysis was performed immediately within half an hour after collection of blood samples into EDTA tube after venipuncture to prevent platelet activation in vitro .…”
Section: Methodsmentioning
confidence: 99%
“…The detection limits are both relevant to the clinical ranges achieved using standard antibody-based immunoassays to evaluate the diagnosis or prognosis PCa patients [100]. Zhao et al used a dual-labeled CL immunoassay to simultaneously measure tPSA and fPSA from diluted human serum samples in just over 1 h [102]. A sandwich immunoassay was also used, in which capture monoclonal antibodies were first immobilized on the sensing platform.…”
Section: Chemiluminescencementioning
confidence: 99%
“…In contrast to CL, electrochemiluminescence (ECL) is electrochemically generated, and therefore electron transfer at or near the working electrode is initiated and manipulated only Zhao et al used a dual-labeled CL immunoassay to simultaneously measure tPSA and fPSA from diluted human serum samples in just over 1 h [102]. A sandwich immunoassay was also used, in which capture monoclonal antibodies were first immobilized on the sensing platform.…”
Section: Electrochemiluminescencementioning
confidence: 99%
See 2 more Smart Citations