2019
DOI: 10.1109/tie.2018.2844840
|View full text |Cite
|
Sign up to set email alerts
|

Dual Passive Harmonic Reduction at DC Link of the Double-Star Uncontrolled Rectifier

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
20
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(21 citation statements)
references
References 10 publications
1
20
0
Order By: Relevance
“…In this paper, the flux density is taken as 0.8 T, and the current density is considered as 2.3 A/mm 2 . Noted that to minimize the current THD, it has been demonstrated in [35] and [38] that the secondary to primary turn ratio must be 10.74 and 5.06, respectively, but in the proposed IPT, this turn ratio is 21.48, which is in a good agreement with the results presented in Fig. 6.…”
Section: B Novel Pulse Tripling Circuit (Ptc)supporting
confidence: 87%
See 1 more Smart Citation
“…In this paper, the flux density is taken as 0.8 T, and the current density is considered as 2.3 A/mm 2 . Noted that to minimize the current THD, it has been demonstrated in [35] and [38] that the secondary to primary turn ratio must be 10.74 and 5.06, respectively, but in the proposed IPT, this turn ratio is 21.48, which is in a good agreement with the results presented in Fig. 6.…”
Section: B Novel Pulse Tripling Circuit (Ptc)supporting
confidence: 87%
“…However, the rating of the multitapped IPT used in [35], is 2.68% and that of the suggested IPT used in the proposed PTC is 1.57%. Also, the rating of this 36-PR based on star autotransformer [35] and star transformer [38] was approximately 48% and more than 100% of the load power, respectively. But, the proposed 36-PR, which is based on polygon autotransformer of this paper, has the rating of 24.16% of the load rating, which is 10.78% less than the one given in [35].…”
Section: B Novel Pulse Tripling Circuit (Ptc)mentioning
confidence: 99%
“…The THDi of a signal is a measurement of the harmonic distortion present and defined as the ratio of the sum of the powers of all harmonic components to the power of the fundamental frequency [31], which is expressed as follows:…”
Section: Thdi Extractionmentioning
confidence: 99%
“…According to lots of efforts have been made to improve the power quality in MPR [4]- [16], increasing the pulse number of MPR is the common and effective way which can be divided into three types of method. The first method is to increase the pulse number of phase-shift transformer to improve the harmonic reduction ability [4]- [6].…”
Section: Introductionmentioning
confidence: 99%
“…The third method is installing auxiliary circuit with the active or passive devices at dc or ac side of MPR [10]- [16]. Actually, the active auxiliary circuit controls the currents through the active devices to be a particular waveform and modulates the output currents of the three-phase diode-bridge rectifiers to meet some conditions.…”
Section: Introductionmentioning
confidence: 99%