2006
DOI: 10.1049/ip-epa:20050215
|View full text |Cite
|
Sign up to set email alerts
|

Dual three-phase induction motor drive with digital current control in the stationary reference frame

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
39
0
1

Year Published

2010
2010
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 99 publications
(41 citation statements)
references
References 26 publications
1
39
0
1
Order By: Relevance
“…1 [10], where the machine has two sets of three-phase windings, one set is designated as ABC, and the other set is XYZ shifted by 30° electrical degrees. Numerous current control strategies have been developed for the dual three-phase drive system [4][5][6][7][11][12][13][14][15][16][17][18]. Two of the most interesting and widely used strategies are the vector space decomposition (VSD) control [11,13,16,17], which treats the machine as a six-phase machine, and the twoindividual current control [4,5,7,12], which treats the machine as two single three-phase machines.…”
Section: Introductionmentioning
confidence: 99%
“…1 [10], where the machine has two sets of three-phase windings, one set is designated as ABC, and the other set is XYZ shifted by 30° electrical degrees. Numerous current control strategies have been developed for the dual three-phase drive system [4][5][6][7][11][12][13][14][15][16][17][18]. Two of the most interesting and widely used strategies are the vector space decomposition (VSD) control [11,13,16,17], which treats the machine as a six-phase machine, and the twoindividual current control [4,5,7,12], which treats the machine as two single three-phase machines.…”
Section: Introductionmentioning
confidence: 99%
“…8 shows the practical results for the speed reversal of the QIM. The speed reference of the QIM is changed from 100 to -100 rad/s linearly in 1 second for t ∈ [5,6]and the stator flux reference is kept constant at 0.4 Wb. The stator flux of the machine is shown in Fig.…”
Section: Practical Resultsmentioning
confidence: 99%
“…3 shows the equivalent circuits of a QIM. The stator and rotor voltage equations of the machine are given as [5]:…”
Section: Description and Modeling Of The Drive Systemmentioning
confidence: 99%
“…If the angle between two of the three phase windings is γ = 60 • , the loss in the 6k ± 1, (k = 1, 3, ...) harmonics is zero and there is no need to improve this loss. Speed control of a six-phase induction machine can be accomplished by many approaches such as FOC [2], [6], [7] and DTC. Direct Torque Control of a six-phase induction machine has been reported in [3], [8]- [10].…”
Section: Introductionmentioning
confidence: 99%