Laser ablation of bone for the purposes of osteotomy is not as well understood as ablation of homogeneous, non-biological materials such as metals and plastics. Ignition times and etch rate can vary during ablation of cortical bone. In this study, we propose the use of two techniques to optimize bone ablation at 1064nm using a coaxial nitrogen jet as an assist gas and topical application of graphite as a highly absorbing chromophore. We show a two order of magnitude reduction in mean time to ignition and variance by using the graphite topical chromophore. We also show that an increase in volumetric flow rate of the assist gas jet does show an initial increase in etch rate, but increased pressure beyond a certain point shows decreased return. This study also demonstrates a 2 nd order relationship between exposure time, volumetric flow rate of nitrogen, and etch rate of cortical bone. The results of this study can be used to optimize the performance of laser ablation systems for osteotomy. This is a companion study to an earlier one carried out by Wong et al. [Biomedical Opt. Express 6, 1 (2015)].