2019
DOI: 10.1007/s00604-019-3370-4
|View full text |Cite
|
Sign up to set email alerts
|

Dually functional polyethylenimine-coated gold nanoparticles: a versatile material for electrode modification and highly sensitive simultaneous determination of four tumor markers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(16 citation statements)
references
References 34 publications
0
16
0
Order By: Relevance
“…In addition, Putnin prepared a sort of dually functional polyethylenimine (PEI)-coated gold nanoparticles as immunoprobes, using the strong electrostatic adsorption to loading of four different types of metal ions, including lead(II) ions, copper(II) ions, cadmium(II) ions, and silver ions [ 63 ]. On account of four independent voltammetric signals generated by these four metal ions, which were posited at −0.80, −0.55, −0.20, and +0.05 V, respectively, this multiplexed electrochemical immunosensor can efficaciously detect AFP, CEA, PSA, and interleukin-8 (IL-8).…”
Section: Electrochemical Signal Substances For Multiplexed Immunoassaymentioning
confidence: 99%
“…In addition, Putnin prepared a sort of dually functional polyethylenimine (PEI)-coated gold nanoparticles as immunoprobes, using the strong electrostatic adsorption to loading of four different types of metal ions, including lead(II) ions, copper(II) ions, cadmium(II) ions, and silver ions [ 63 ]. On account of four independent voltammetric signals generated by these four metal ions, which were posited at −0.80, −0.55, −0.20, and +0.05 V, respectively, this multiplexed electrochemical immunosensor can efficaciously detect AFP, CEA, PSA, and interleukin-8 (IL-8).…”
Section: Electrochemical Signal Substances For Multiplexed Immunoassaymentioning
confidence: 99%
“…Error bars showed the standard deviation (SD) of five detections. The LOD of E. coli O157:H7 analyzed using the LFIA strips was 50 cells/mL based on the IUPAC formula (LOD = y blank + 3 × SD blank , where y blank and SD blank are the average Raman intensity and the SD of the blank control, respectively) (Hu et al, 2017;Putnin et al, 2019). The SiO 2 /Au-based SERS-LFIA strips were characterized by SEM to prove that the SERS signal came from the SERS tags fixed on the test line.…”
Section: Optimization Of Sers-based Lfia Stripsmentioning
confidence: 99%
“…DPV was used for the detection of the oxidation peaks of Cu, Zn, and Pb ions obtained by acid dissolution of the hybrid NPS at +0.8, +1.3, and +0.1 V, respectively [ 78 ] A similar study was done by Putnin et al with polyethylenimine-coated gold nanoparticles (PEI-AuNPs) conjugated with four different electroactive metal ions—Cd (II), Ag (I), Pb (II), and Cu (II)—as labels. They also used the same PEI-AuNPs for surface modification of the SPEs and detected four tumor biomarkers—PSA, AFP, CEA, and interleukin-8 (IL-8)—with LODs from 0.9 to 1.7 fg mL −1 [ 79 ].…”
Section: Immunoassay Techniques For Printed Electrodesmentioning
confidence: 99%
“…Their findings indicate larger surface areas hinder reaching ultrasensitive measurements and suppression of the background signal can easily be achieved by minimal surface area [ 139 ]. We have already presented many examples of signal amplification by surface modification of SPE’s by nanoparticles [ 17 , 79 , 90 , 91 , 93 , 94 , 95 , 96 , 97 , 98 , 99 , 100 , 101 , 102 , 103 , 109 , 110 , 111 ]. A few more examples are included in this section.…”
Section: Screen Printingmentioning
confidence: 99%