2022
DOI: 10.1002/smll.202106567
|View full text |Cite
|
Sign up to set email alerts
|

Dumbbell Plate‐Shaped AIEgen‐Based Luminescent MOF with High Quantum Yield as Self‐Enhanced ECL Tags: Mechanism Insights and Biosensing Application

Abstract: low background interference, and easy operation. [4][5][6][7] Nowadays, ECL with these favorable benefits has become one powerful analytical technique applied in biomarkers, food safety, and environmental pollutants analyses. [8][9][10][11] As it is well known, the high sensitivity for the ECLbased immunoassays was mainly attributable to the excellent luminophores. [12] At present, most of the reported methods used nanomaterials like multi-porous nanoparticles (NPs) [13,14] or metal−organic frameworks (MOFs) [… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
48
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 61 publications
(48 citation statements)
references
References 46 publications
0
48
0
Order By: Relevance
“…The flat-band potential ( E fb ) of POM-ZrO 2 was reckoned with −0.82 V versus SCE (−0.58 V vs NHE) based on the X-intercept of the tangent line (Figure S8C). The conduction band (CB) level ( E cb ), about 0.2 V lower than E fb , was about −0.78 V relative to NHE. Thus, the valence band (VB) potential ( E vb ) could be calculated as 2.25 V relative to NHE based on the formula E g = E vb – E cb .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The flat-band potential ( E fb ) of POM-ZrO 2 was reckoned with −0.82 V versus SCE (−0.58 V vs NHE) based on the X-intercept of the tangent line (Figure S8C). The conduction band (CB) level ( E cb ), about 0.2 V lower than E fb , was about −0.78 V relative to NHE. Thus, the valence band (VB) potential ( E vb ) could be calculated as 2.25 V relative to NHE based on the formula E g = E vb – E cb .…”
Section: Resultsmentioning
confidence: 99%
“…First, the CV of the modified electrode with POM-ZrO 2 was measured at a series of different scanning rates from 0.02 to 0.20 V/s for calculating the electrochemically active area of the electrode. , The complete calculation process can be seen in the Supporting Information. The electrochemical active area was calculated to be 0.1648 cm 2 based on the formula, while the actual area of bare GCE was 0.1256 cm 2 (Φ = 4 mm).…”
Section: Resultsmentioning
confidence: 99%
“…5B). 81 As a typical tumor marker, the detection of cytokeratin 19 fragment 21-1 (CYFRA 21-1) is of great significance. Wei synthesized an Ir( ppy) 3 @apoFt bioconjugate with AIECL characteristics as a probe.…”
Section: Application In Protein Markersmentioning
confidence: 99%
“…In addition, the authors combined Zr-TCBPE-MOF with polyethyleneimine (PEI) to prepare a unique self-reinforced Zr-TCBPE-PEI electroluminescent complex, which could effectively avoid the bio-toxicity of the co-reactant and exhibit a more dramatic ECL response. The prepared ECL sensor showed good correlation in the range of 0.0001–10 ng/mL and the lower LOD was 52 fg/mL, providing an effective way for the early and sensitive detection of small cell lung cancer [ 64 ].…”
Section: Synthesis Of Porous Nanomaterials With Ecl Propertiesmentioning
confidence: 99%
“… Schematic illustration for the synthesis of ( A ) Zr-TCBPE-PEI-Ag NPs substrate and ( B ) Ab 2 -AuPd@SiO 2 bioconjugate, and ( C ) the fabrication process of the proposed ECL immunosensor with possible ECL-enhancing effects and luminescence mechanism [ 64 ]. Copyright © 2022, John Wiley and Sons.…”
Section: Figurementioning
confidence: 99%