2020
DOI: 10.1007/s10384-020-00714-7
|View full text |Cite
|
Sign up to set email alerts
|

Duration of room air tamponade after vitrectomy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 16 publications
0
5
2
Order By: Relevance
“…The duration of the half-life of air differs from study to study; it was 4.8 ± 0.6 days in the present study, 1.6 days in a study conducted by Thompson in 1898 14 , and approximately 3.3 days in a study conducted by Lee et al in 2020 15 . Su cient shaving of the peripheral vitreous was associated with an increased amount of air injection, leading to the extension of the half-life of air.…”
Section: Discussioncontrasting
confidence: 60%
“…The duration of the half-life of air differs from study to study; it was 4.8 ± 0.6 days in the present study, 1.6 days in a study conducted by Thompson in 1898 14 , and approximately 3.3 days in a study conducted by Lee et al in 2020 15 . Su cient shaving of the peripheral vitreous was associated with an increased amount of air injection, leading to the extension of the half-life of air.…”
Section: Discussioncontrasting
confidence: 60%
“…[ 30–35 ] These studies may not be representative of current practice, especially with regards to the duration of the air bubble in the posterior chamber of the eye, which is perceived to be longer in clinical settings than in theoretical ones. [ 36,37 ] The half‐life of intraocular gases is shorter in aphakic eyes than in phakic eyes, due to the increased convection in the vitreous cavity. [ 38 ] Following the vitrectomy procedure, convection currents appear in the aphakic eye, which accelerate the absorption rate.…”
Section: Vitreous Substitutes In Clinical Practicementioning
confidence: 99%
“…In a recent retrospective cohort study, a half‐life of 3.3 d with a longevity of 11.4 d was determined. [ 37 ]…”
Section: Vitreous Substitutes In Clinical Practicementioning
confidence: 99%
“…Some studies show that sterilizing air can also be used for macular hole repair and achieve satisfactory results [3][4][5][6][7]. e advantage of sterilizing air is that the time of prone position is short [8], which is not easy to cause high intraocular pressure. However, the disadvantage is that the absorption time of sterilizing air is short so that the closure rate in the large size of macular hole is lower than inflating gas [9].…”
Section: Introductionmentioning
confidence: 99%