2012
DOI: 10.1117/12.912081
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic focus optical coherence tomography: feasibility for improved basal cell carcinoma investigation

Abstract: Basal cell carcinoma (BCC) is the most common form of skin cancer. To improve the diagnostic accuracy, additional non-invasive methods of making a preliminary diagnosis have been sought. We have implemented an En-Face optical coherence tomography (OCT) for this study in which the dynamic focus was integrated into it. With the dynamic focus scheme, the coherence gate moves synchronously with the peak of confocal gate determined by the confocal interface optics. The transversal resolution is then conserved throu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 17 publications
0
3
0
Order By: Relevance
“…We previously found three main features in the BCC OCT images: (1) lobular pattern of abnormal architecture, (2) dilated blood vessels, and (3) highly reflective margins. In addition to these [35][36][37][38] features, by using the DF-OCT, some new features associated with BCC were identified. These features are as follows: (a) irregular architecture of the skin layers (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…We previously found three main features in the BCC OCT images: (1) lobular pattern of abnormal architecture, (2) dilated blood vessels, and (3) highly reflective margins. In addition to these [35][36][37][38] features, by using the DF-OCT, some new features associated with BCC were identified. These features are as follows: (a) irregular architecture of the skin layers (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Examples of OCT, RCT, and ultrasonography images of melanoma are shown in Figure 9 . It should be noted that many of these imaging modalities are in the investigational phase (see [ 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 , 78 , 79 , 80 , 81 , 82 , 83 , 84 ]); i.e., they are not regularly used in clinical practice as of yet, but they could provide promising options in the future when they are better understood and accessible.…”
Section: Melanoma Biomarkersmentioning
confidence: 99%
“…Therefore to produce a solid phantom, the ratio of 3 0.5∶1 epoxy to hardener should always be used. The solidness of the phantom is important in several applications; for instance, with OCT setups with horizontal sample arms, a dough-like phantom cannot be used [26][27][28].…”
Section: Phantom Recipementioning
confidence: 99%