1999
DOI: 10.1002/(sici)1096-9918(199905/06)27:5/6<354::aid-sia541>3.0.co;2-4
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic force microscopy in fluid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

1999
1999
2016
2016

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 68 publications
(13 citation statements)
references
References 20 publications
0
13
0
Order By: Relevance
“…However, when a cantilever is in permanent contact with a stiff sample such as mica, the tip is not moving up and down (the indentation is small because the sample is stiff), but the cantilever is still flexing due to the base motion. Because the optical beam deflection method measures the slope at the free end of the cantilever, there is still some measured motion [25], which we refer to as the residual amplitude A res and phase φ res . Some authors [13] have suggested that A res ≈ Y and thus used A res to measure Y (and then A fluid ).…”
Section: Proposed Methods To Quantitatively Determine the Fluid-borne mentioning
confidence: 99%
“…However, when a cantilever is in permanent contact with a stiff sample such as mica, the tip is not moving up and down (the indentation is small because the sample is stiff), but the cantilever is still flexing due to the base motion. Because the optical beam deflection method measures the slope at the free end of the cantilever, there is still some measured motion [25], which we refer to as the residual amplitude A res and phase φ res . Some authors [13] have suggested that A res ≈ Y and thus used A res to measure Y (and then A fluid ).…”
Section: Proposed Methods To Quantitatively Determine the Fluid-borne mentioning
confidence: 99%
“…The equivalent mechanical system is a spring in series with a spring and a dashpot. By assuming a contact mechanism as described by Hertz contact mechanics, we deduce the force as (21) where E 0 and E ∞ represent the Young's modulus of the material at fast and slow loading rates, respectively.…”
Section: Standard Linear Solid Viscoelastic Model (Sls)mentioning
confidence: 99%
“…In the process, the cross talk between modes and harmonics has been clarified [16][17][18][19][20]. The complicated cantilever motion in liquid and the differences observed between the excitation methods have been analyzed by simulations [21][22][23].…”
Section: Introductionmentioning
confidence: 99%
“…A commercial atomic force microscope (Nanoscope IIIa with Multi Mode head, Veeco Digital Instruments) with a liquid cell was used with either magnetic or acoustic excitation. To enable magnetic excitation (Han et al, 1996;Lantz et al, 1999) a coil was wound into a recess in the fluid cell normally used to retain a rubber o-ring. Both methods used silicon nitride cantilevers with a nominal spring constant of 0.37 N/m.…”
Section: Methodsmentioning
confidence: 99%